{"title":"Badger Industry Guard Nozzles","description":"","products":[{"product_id":"range-guard-threeway","title":"Badger Three-way Nozzle - 83-100037-001","description":"\u003cbody\u003e\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eBadger Industry Guard Three-Way Nozzle | Dry Chemical | 83-100037-001 | Sold Individually\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section{max-width:100%;margin:2rem 0;font-family:Arial,sans-serif;color:#333}.accordion-item{border-bottom:1px solid #ddd}.accordion-header{display:flex;justify-content:space-between;padding:2rem 0;cursor:pointer;background:none;border:none;width:100%;text-align:left;color:#333}.accordion-header:hover,.accordion-header:focus{color:#333;background:none;outline:none}.accordion-title{font-size:1.5rem;font-weight:500}.accordion-icon{font-size:1.5rem}.accordion-item.active .accordion-icon{transform:rotate(180deg)}.accordion-content{max-height:0;overflow:hidden}.accordion-item.active .accordion-content{max-height:none}.accordion-content-inner{font-size:1.4rem;line-height:1.7;color:#555;padding-bottom:2rem}.accordion-content-inner p{margin:0 0 1rem 0}.specs-table{width:100%;border-collapse:collapse}.specs-table th,.specs-table td{border:1px solid #ddd;padding:.75rem 1rem;font-size:1.4rem;text-align:left}.specs-table th{background-color:#f5f5f5;font-weight:600;color:#333}\n\u003c\/style\u003e\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Badger Industry Guard Three-Way Nozzle (P\/N 83-100037-001) discharges dry chemical agent in three simultaneous directions and is designed for pit, tunnel, or plenum and stack interface applications in the Badger Industry Guard Industrial Dry Chemical Fire Suppression System. The three-direction discharge pattern allows a single nozzle position to provide agent coverage across a wide or multi-directional area that would otherwise require multiple single-direction nozzles. Sold individually. For full background on the Badger Industry Guard nozzle family and system requirements, refer to the total flooding nozzle product page (P\/N 83-100005-001).\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBadger Fire Protection (Kidde-Fenwal)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e83-100037-001\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNozzle Type\u003c\/td\u003e\n\u003ctd\u003eThree-Way\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDischarge Pattern\u003c\/td\u003e\n\u003ctd\u003eThree-Direction Simultaneous Discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePit, Tunnel, or Plenum and Stack Interface Areas\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAgent Type\u003c\/td\u003e\n\u003ctd\u003eABC Dry Chemical\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSold As\u003c\/td\u003e\n\u003ctd\u003eSingle Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eBadger Industry Guard Industrial Dry Chemical Fire Suppression System\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRelated Nozzles\u003c\/td\u003e\n\u003ctd\u003eTotal Flooding: P\/N 83-100005-001 | Tankside: P\/N WK-259072-000\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003edocument.addEventListener('DOMContentLoaded',function(){document.querySelectorAll('.accordion-header').forEach(h=\u003eh.addEventListener('click',function(){this.parentElement.classList.toggle('active')}))});\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"Product\",\"name\":\"Badger Industry Guard Three-Way Nozzle | Dry Chemical | 83-100037-001 | Sold Individually\",\"description\":\"OEM Three-Way nozzle for the Badger Industry Guard Industrial Dry Chemical Fire Suppression System. Three-direction simultaneous discharge for pit, tunnel, or plenum and stack interface applications. Sold individually.\",\"sku\":\"83-100037-001\",\"mpn\":\"83-100037-001\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Badger Fire Protection\"},\"category\":\"Fire Suppression Equipment\"}\n\u003c\/script\u003e\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":45899312070821,"sku":"Range-Guard-Threeway","price":78.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/badger-simple-default-title-badger-three-way-nozzle-83-100037-001-33259523342501_2447d2c3-9539-4995-b80c-45b6df16e2d0.webp?v=1771286843"},{"product_id":"range-guard-total-flooding-nozzle","title":"Badger Total Flooding Nozzle, Single Item - 83-100005-001","description":"\u003cbody\u003e\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eBadger Industry Guard Total Flooding Nozzle | Dry Chemical | 83-100005-001 | Sold Individually\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section{max-width:100%;margin:2rem 0;font-family:Arial,sans-serif;color:#333}.accordion-item{border-bottom:1px solid #ddd}.accordion-header{display:flex;justify-content:space-between;padding:2rem 0;cursor:pointer;background:none;border:none;width:100%;text-align:left;color:#333}.accordion-header:hover,.accordion-header:focus{color:#333;background:none;outline:none}.accordion-title{font-size:1.5rem;font-weight:500}.accordion-icon{font-size:1.5rem}.accordion-item.active .accordion-icon{transform:rotate(180deg)}.accordion-content{max-height:0;overflow:hidden}.accordion-item.active .accordion-content{max-height:none}.accordion-content-inner{font-size:1.4rem;line-height:1.7;color:#555;padding-bottom:2rem}.accordion-content-inner p{margin:0 0 1rem 0}.accordion-content-inner ul{margin:0 0 1rem 0;padding-left:2rem}.accordion-content-inner li{margin-bottom:.4rem}.accordion-content-inner h3{font-size:1.4rem;font-weight:600;color:#333;margin:1.5rem 0 .5rem 0}.specs-table{width:100%;border-collapse:collapse}.specs-table th,.specs-table td{border:1px solid #ddd;padding:.75rem 1rem;font-size:1.4rem;text-align:left}.specs-table th{background-color:#f5f5f5;font-weight:600;color:#333}\n\u003c\/style\u003e\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Badger Industry Guard Total Flooding Nozzle (P\/N 83-100005-001) is an overhead dry chemical nozzle for total flood protection configurations in the Badger Industry Guard Industrial Dry Chemical Fire Suppression System. In a total flood application, the nozzle discharges agent from an overhead or upper-perimeter position to fill an enclosed hazard space with enough dry chemical agent to extinguish a fire anywhere in that volume, rather than targeting a specific surface. The Industry Guard system is Badger's pre-engineered dry chemical system for industrial high-hazard applications including spray booths, dip tanks, mixing rooms, and similar occupancies, and is governed by NFPA 17 (Dry Chemical Extinguishing Systems).\u003c\/p\u003e\n      \u003cp\u003eThe nozzle family for the Badger Industry Guard system includes this total flooding nozzle, along with a three-way nozzle (P\/N 83-100037-001) for pit, tunnel, or plenum\/stack interface applications, and a tankside nozzle (P\/N WK-259072-000) for side-mounted local application. Each nozzle type is specified based on the protected hazard geometry and the discharge pattern required by the system design. Nozzle selection, placement, and spacing are determined by a certified Badger Industry Guard installer per the system design manual. Sold individually.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBadger Fire Protection (Kidde-Fenwal)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e83-100005-001\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNozzle Type\u003c\/td\u003e\n\u003ctd\u003eTotal Flooding\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAgent Type\u003c\/td\u003e\n\u003ctd\u003eABC Dry Chemical\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSold As\u003c\/td\u003e\n\u003ctd\u003eSingle Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eBadger Industry Guard Industrial Dry Chemical Fire Suppression System\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eGoverning Standard\u003c\/td\u003e\n\u003ctd\u003eNFPA 17 (Dry Chemical Extinguishing Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRelated Nozzles\u003c\/td\u003e\n\u003ctd\u003eThree-Way: P\/N 83-100037-001 | Tankside: P\/N WK-259072-000\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eInstallation and Compliance\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCertified Installer Required:\u003c\/strong\u003e The Badger Industry Guard system must be designed, installed, and serviced by a certified Badger Industry Guard distributor following the system design manual. Nozzle placement must match the engineered design exactly.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eNozzle Cap:\u003c\/strong\u003e Confirm the blow-off cap is in place and undamaged at each inspection. Replace after any actuation or if the cap is found damaged during service.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSemiannual Service:\u003c\/strong\u003e A certified technician inspects all nozzles for orifice blockage, corrosion, and correct positioning at each required service interval.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eWhat is the difference between total flood and local application protection?\u003c\/h3\u003e\n      \u003cp\u003eTotal flood protection fills an enclosed space with enough dry chemical agent to extinguish any fire within that volume, regardless of where the fire is located. Local application directs agent specifically at the surface or object that is burning, without attempting to flood the entire space. The correct approach for a given hazard is determined during system design based on the hazard geometry, the presence or absence of enclosure walls, and the nature of the burning materials.\u003c\/p\u003e\n      \u003ch3\u003eCan this nozzle be used in other dry chemical systems?\u003c\/h3\u003e\n      \u003cp\u003eNo. This nozzle is specifically designed and listed for use in the Badger Industry Guard system. Its orifice dimensions, flow characteristics, and discharge patterns have been tested and listed for that system's specific design parameters. Using it in another manufacturer's system would be outside the component's listing and void that system's certification.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003edocument.addEventListener('DOMContentLoaded',function(){document.querySelectorAll('.accordion-header').forEach(h=\u003eh.addEventListener('click',function(){this.parentElement.classList.toggle('active')}))});\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"Product\",\"name\":\"Badger Industry Guard Total Flooding Nozzle | Dry Chemical | 83-100005-001 | Sold Individually\",\"description\":\"OEM Total Flooding nozzle for the Badger Industry Guard Industrial Dry Chemical Fire Suppression System. Overhead discharge, fills enclosed hazard space with dry chemical agent. Sold individually. Per NFPA 17.\",\"sku\":\"83-100005-001\",\"mpn\":\"83-100005-001\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Badger Fire Protection\"},\"category\":\"Fire Suppression Equipment\"}\n\u003c\/script\u003e\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":45899312103589,"sku":"Range-Guard-Total-Flooding-Nozzle","price":66.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/badger-simple-default-title-badger-total-flooding-nozzle-single-item-83-100005-001-33269775925413_ab7c1957-0fd8-487e-bc92-0add0ef1cd51.webp?v=1771286843"},{"product_id":"badger-high-overhead-nozzle-259270","title":"Badger High Overhead Nozzle - 83-259270-000","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eBadger 83-259270-000 High Overhead Nozzle | Dry Chemical Series\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Badger 83-259270-000 (also referenced as 259270) is a precision dry chemical nozzle engineered for high-overhead area protection in industrial environments. Where low-overhead nozzles are optimized for proximity, the 83-259270-000 is designed for the long throw -- delivering sufficient kinetic energy to propel dry chemical agent from ceiling height to the hazard below without being dissipated by building ventilation. It is the standard nozzle for Industry Guard systems protecting large-scale manufacturing zones, spray booths, and similar applications.\u003c\/p\u003e\n        \u003cp\u003eConstructed from nickel-chrome plated brass, the 83-259270-000 resists the corrosive vapors and particulate buildup common in industrial settings. Its internal strainer manages laminar flow to produce a cohesive solid cone pattern, ensuring the center of the hazard receives the same agent density as the perimeter and preventing burn-through. Using this genuine OEM nozzle is a mandatory requirement for maintaining the UL listed status of an Industry Guard system -- the discharge must match the pre-calculated hydraulic design.\u003c\/p\u003e\n\n        \u003ch3\u003eHigh Overhead vs. Low Overhead: Field Distinction\u003c\/h3\u003e\n        \u003cp\u003eThe 83-259270-000 high overhead nozzle lacks the heavy velocity-reduction screen of the low overhead (83-844258-000) model, preserving enough kinetic energy for the agent to reach the floor from ceiling mount heights. The low overhead version features a dense screen specifically to soften the discharge for proximity mounting above dip tanks, where splash prevention is critical. Substituting a high overhead nozzle in a low overhead application will cause dangerous splashing; using a low overhead nozzle at ceiling height will result in the agent floating away in the ventilation draft.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003eBadger Fire Protection\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e83-259270-000 (259270)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eNozzle Style\u003c\/td\u003e\n              \u003ctd\u003eHigh-overhead, area protection\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eMaterial\u003c\/td\u003e\n              \u003ctd\u003eNickel-chrome plated brass\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eInlet Thread\u003c\/td\u003e\n              \u003ctd\u003e3\/8\" NPT (Female)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFlow Point Rating\u003c\/td\u003e\n              \u003ctd\u003e2 Flow Points\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSystem\u003c\/td\u003e\n              \u003ctd\u003eIndustry Guard dry chemical\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eAgent Compatibility\u003c\/td\u003e\n              \u003ctd\u003eABC, BC, Purple-K dry chemical agents\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Maintenance \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eMaintenance \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eBlow-Off Cap Mandate\u003c\/h3\u003e\n        \u003cp\u003eIn paint booth and spray environments, the orifice is constantly exposed to overspray. Every 83-259270-000 must be fitted with an OEM replacement cap to prevent the internal strainer from becoming blocked by hardened paint. The cap pops off instantly under system discharge pressure.\u003c\/p\u003e\n\n        \u003ch3\u003eOrifice and Plating Audit\u003c\/h3\u003e\n        \u003cp\u003eDuring each semi-annual NFPA 17 inspection, verify that the nickel-chrome plating is intact. Peeling plating can trap dry chemical agent in the orifice, causing internal caking that restricts flow. Any nozzle showing obstruction or plating failure must be replaced immediately.\u003c\/p\u003e\n\n        \u003ch3\u003eAlignment Verification\u003c\/h3\u003e\n        \u003cp\u003eHigh-ceiling nozzles are susceptible to being knocked out of alignment during facility maintenance. A nozzle aimed even 10 degrees off-target can leave a significant shadow zone where a fire can continue to burn unchecked. Verify aim at every inspection using the system's as-built drawings.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan this nozzle be used in a Range Guard wet chemical system?\u003c\/h3\u003e\n        \u003cp\u003eNo. The 83-259270-000 is calibrated for the particle size and flow dynamics of dry chemical agents. Using it in a wet chemical system will cause an immediate clog and system failure.\u003c\/p\u003e\n\n        \u003ch3\u003eWhich agent types are compatible?\u003c\/h3\u003e\n        \u003cp\u003eThe nozzle is designed for all standard dry chemical agents, including ABC powder, BC agent, and Purple-K. It is not compatible with wet chemical or foam agents.\u003c\/p\u003e\n\n        \u003ch3\u003eDoes this nozzle include mounting hardware?\u003c\/h3\u003e\n        \u003cp\u003eNo. The part number refers to the nozzle body only. Installation requires a standard 3\/8\" NPT connection to the discharge piping. Mounting hardware must be sourced separately based on the ceiling substrate and installation configuration.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Badger 83-259270-000 High Overhead Nozzle | Dry Chemical Series\",\n  \"description\": \"High-overhead dry chemical nozzle for Badger Industry Guard fire suppression systems. Nickel-chrome plated brass body, 3\/8\\\" NPT female inlet, 2 flow point rating. Internal strainer produces cohesive solid cone discharge pattern for area protection from ceiling-mount heights. Compatible with ABC, BC, and Purple-K agents. Requires OEM blow-off cap. Semi-annual NFPA 17 inspection required. Not compatible with wet chemical systems. Mounting hardware sold separately.\",\n  \"sku\": \"83-259270-000\",\n  \"mpn\": \"83-259270-000\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Badger Fire Protection\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Badger Fire Protection\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nozzle Style\",\n      \"value\": \"High-overhead area protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Material\",\n      \"value\": \"Nickel-chrome plated brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Inlet Thread\",\n      \"value\": \"3\/8 inch NPT Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flow Point Rating\",\n      \"value\": \"2 Flow Points\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"System\",\n      \"value\": \"Industry Guard dry chemical\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Agent Compatibility\",\n      \"value\": \"ABC, BC, Purple-K dry chemical\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":46064169779365,"sku":"259270","price":136.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/BadgerHighOverheadNozzleIndustryGuard83-259270-000_e4dc49bc-94d4-4e41-8162-703e205953d6.webp?v=1771286511"},{"product_id":"badger-industry-guard-duct-plenum-d-p-nozzle-single-item-83-100006-001","title":"Badger Industry Guard Duct Plenum (D\/P) Nozzle, Single Item - 83-100006-001","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eBadger Industry Guard D\/P Nozzle | Duct \u0026amp; Plenum Protection | P\/N 83-100006-001\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Badger 83-100006-001 is the definitive solution for blind-spot fire protection in industrial ventilation systems. While fires on a shop floor are immediate and visible, a fire that infiltrates an exhaust duct or plenum becomes a high-velocity catastrophe -- flames can travel through a building's ventilation spine in seconds. These hidden hazards are found in paint spray booth suppression lines, industrial printing presses, and chemical vapor exhaust systems.\u003c\/p\u003e\n        \u003cp\u003eThe D\/P nozzle is precision-calibrated to deliver a high-velocity discharge of Industry Guard dry chemical agent, achieving a total flood state within the narrow, high-airflow environment of industrial ductwork. By utilizing this OEM component, facility managers ensure their ventilation systems are actively protected by a suppression endpoint that can stop a fire before it reaches secondary structural zones.\u003c\/p\u003e\n\n        \u003ch3\u003ePattern Optimization for High-Airflow Environments\u003c\/h3\u003e\n        \u003cp\u003eUnlike overhead nozzles designed for open space, the 83-100006-001 orifice geometry is engineered for confined, directional airflow. The discharge is calibrated to propel dry chemical agent against active exhaust fan resistance, ensuring the agent coats internal plenum surfaces rather than being prematurely evacuated by the airstream.\u003c\/p\u003e\n\n        \u003ch3\u003eFlow Point Rating and Hydraulic Balancing\u003c\/h3\u003e\n        \u003cp\u003eAs a 1.0 flow point nozzle, the 83-100006-001 allows engineers to protect long runs of exhaust duct by staggering endpoints without over-depleting the main agent cylinder. This granular hydraulic balancing ensures every nozzle in the array receives its required agent volume for complete plenum coverage.\u003c\/p\u003e\n\n        \u003ch3\u003eMaterial Resilience\u003c\/h3\u003e\n        \u003cp\u003eIndustrial exhaust often carries corrosive vapors. The 83-100006-001 is constructed from high-durability alloys that maintain structural integrity even when subjected to years of high-velocity vibration and chemical exposure.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003eBadger Fire Protection \/ Kidde-Fenwal\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e83-100006-001 (also 100006)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eNozzle Style\u003c\/td\u003e\n              \u003ctd\u003eD\/P Nozzle (Duct \u0026amp; Plenum)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eInlet Thread\u003c\/td\u003e\n              \u003ctd\u003e3\/8\" NPT (Female)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSystem\u003c\/td\u003e\n              \u003ctd\u003eIndustry Guard dry chemical\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFlow Point Rating\u003c\/td\u003e\n              \u003ctd\u003e1.0 Flow Point\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eApplication\u003c\/td\u003e\n              \u003ctd\u003eIndustrial ductwork and plenum protection\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompliance\u003c\/td\u003e\n              \u003ctd\u003eNFPA 17\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Maintenance \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eMaintenance \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eGrease and Overspray Audit\u003c\/h3\u003e\n        \u003cp\u003eIn industrial settings, paint overspray can harden on the nozzle tip. A carbonized or blocked orifice will distort the spray pattern and result in insufficient coverage. During every 6-month inspection, any nozzle showing internal accumulation must be replaced rather than cleaned.\u003c\/p\u003e\n\n        \u003ch3\u003eMandatory Blow-Off Cap Protection\u003c\/h3\u003e\n        \u003cp\u003eEvery 83-100006-001 must be fitted with an OEM replacement cap to prevent environmental contamination of the orifice. The cap is designed to rupture instantly under system pressure. Never use tape or non-OEM covers, as they may not release at the calibrated actuation pressure.\u003c\/p\u003e\n\n        \u003ch3\u003eSightline Alignment Verification\u003c\/h3\u003e\n        \u003cp\u003eBecause D\/P nozzles are often hidden inside ductwork, they are frequently bumped during duct cleaning. Technicians must verify at every inspection that the nozzle is aimed directly into the center of the duct run. A nozzle pointing at a duct wall instead of the open plenum creates a shadow zone where a fire can bypass the suppression agent entirely.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan I use a Range Guard wet chemical nozzle in my industrial duct?\u003c\/h3\u003e\n        \u003cp\u003eNo. Wet chemical nozzles are designed for liquid agent viscosity. Using them in an Industry Guard dry chemical system will result in an immediate clog and complete system failure, and constitutes a code violation.\u003c\/p\u003e\n\n        \u003ch3\u003eWhy is the 83-100006-001 better than a generic duct nozzle?\u003c\/h3\u003e\n        \u003cp\u003eGeneric nozzles are not tested for the specific flow dynamics of the Industry Guard agent. OEM nozzles ensure the discharge matches the system's tested volumetric flooding design, providing reliable catastrophic fire mitigation within a known hydraulic envelope.\u003c\/p\u003e\n\n        \u003ch3\u003eDoes this nozzle work for high-proximity dip tank applications?\u003c\/h3\u003e\n        \u003cp\u003eNo. For hazards where the nozzle is mounted close to a liquid surface, a low overhead nozzle with an internal velocity-reduction screen is required. The D\/P nozzle is specifically engineered for high-velocity ventilation environments and would produce dangerous splashing in a dip tank application.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Badger Industry Guard D\/P Nozzle | Duct \u0026 Plenum Protection | P\/N 83-100006-001\",\n  \"description\": \"NFPA 17 compliant D\/P (Duct and Plenum) nozzle for Badger Industry Guard dry chemical fire suppression systems. 3\/8\\\" NPT female inlet, 1.0 flow point rating, high-durability alloy construction. Engineered for volumetric flooding in industrial exhaust ducts, paint spray booths, printing presses, and chemical vapor lines. Requires OEM blow-off cap. Inspect every 6 months; replace if any orifice obstruction or corrosion is present.\",\n  \"sku\": \"83-100006-001\",\n  \"mpn\": \"83-100006-001\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Badger Fire Protection\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Badger Fire Protection \/ Kidde-Fenwal\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nozzle Style\",\n      \"value\": \"D\/P (Duct and Plenum)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Inlet Thread\",\n      \"value\": \"3\/8 inch NPT Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"System\",\n      \"value\": \"Industry Guard dry chemical\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flow Point Rating\",\n      \"value\": \"1.0 Flow Point\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Application\",\n      \"value\": \"Industrial ductwork and plenum protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compliance\",\n      \"value\": \"NFPA 17\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":47352409489573,"sku":null,"price":55.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/Badger-Duct-Plenum-Nozzle-Industry-Guard-83-100006-001_c856bd6f-3652-4da1-91bc-99492632aae9.webp?v=1771286485"},{"product_id":"badger-industry-guard-low-overhead-nozzle-single-item-83-844258-000","title":"Badger Industry Guard Low Overhead Nozzle, Single Item - 83-844258-000","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eKidde-Fenwal \/ Badger 83-844258-000 Low Overhead Nozzle | 3\/8\" NPT | 2 Flow Points\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n  .accordion-item { border-bottom: 1px solid #ddd; }\n  .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; color: #333; }\n  .accordion-header:hover, .accordion-header:focus { color: #333; background: none; outline: none; }\n  .accordion-title { font-size: 1.5rem; font-weight: 500; }\n  .accordion-icon { font-size: 1.5rem; }\n  .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n  .accordion-content { max-height: 0; overflow: hidden; }\n  .accordion-item.active .accordion-content { max-height: none; }\n  .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; padding-bottom: 2rem; }\n  .accordion-content-inner p { margin: 0 0 1rem 0; }\n  .accordion-content-inner ul { margin: 0 0 1rem 0; padding-left: 2rem; }\n  .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; color: #333; margin: 1.5rem 0 0.5rem 0; }\n  .specs-table { width: 100%; border-collapse: collapse; }\n  .specs-table th, .specs-table td { border: 1px solid #ddd; padding: 0.75rem 1rem; font-size: 1.4rem; text-align: left; }\n  .specs-table th { background-color: #f5f5f5; font-weight: 600; color: #333; }\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-section\"\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Kidde-Fenwal 83-844258-000 (also referenced as 844258) is a precision-engineered low overhead nozzle for dry chemical local application. In industrial environments where open-top tanks of flammable liquids are present, a high-velocity discharge is counterproductive -- if the suppressant strikes the surface too hard, it can splash flaming liquid onto the facility floor and create a running fuel fire. The 83-844258-000 solves this with an internal velocity-reduction screen that converts high-pressure kinetic energy into a controlled, low-velocity solid cone spray pattern, allowing ABC, BC, or Purple-K agents to settle onto the hazard surface like a blanket rather than an impact tool.\u003c\/p\u003e\n      \u003cp\u003eThis soft-landing capability is a safety mandate for dip tanks and quench tank applications where oil-based hazards require a gentle but high-volume application to achieve total flame knockdown without splash. The 2 flow point rating provides a high-volume delivery that is mathematically balanced for Kidde-Fenwal and Badger manifolds, ensuring every nozzle in a multi-tank array receives the exact agent volume required.\u003c\/p\u003e\n      \u003ch3\u003eLow Overhead vs. High Overhead\u003c\/h3\u003e\n      \u003cp\u003eLow overhead nozzles like the 83-844258-000 are intended for mounting heights close to the hazard. The internal velocity-reduction screen is the defining feature, enabling soft-landing discharge mandatory for open-top tanks where splashing is a risk. High overhead nozzles rely on high-velocity reach to push agent through a heat plume at greater distances and lack an internal screen entirely. Substituting a high overhead nozzle in a quench tank application is a critical safety violation and voids the UL\/FM listing.\u003c\/p\u003e\n      \u003ch3\u003eNickel-Chrome Plated Brass Construction\u003c\/h3\u003e\n      \u003cp\u003eThe nickel-chrome plating provides superior resistance to the caustic vapors found near dip tanks and paint booths compared to standard brass, keeping the orifice dimensions precise and the threads structurally sound over a 10-year service life in aggressive solvent environments.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBadger Fire Protection \/ Kidde-Fenwal\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e83-844258-000 (844258)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNozzle Style\u003c\/td\u003e\n\u003ctd\u003eLow Overhead (Local Application)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eInlet Thread\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPT (Female)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eNickel-chrome plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFlow Point Rating\u003c\/td\u003e\n\u003ctd\u003e2 Flow Points\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eInternal Component\u003c\/td\u003e\n\u003ctd\u003eStainless steel velocity-reduction screen\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eMaintenance \u0026amp; Compliance\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eBlow-Off Cap Protection\u003c\/h3\u003e\n      \u003cp\u003eEvery low overhead nozzle must be fitted with a 83-259100-000 nozzle cap to prevent grease, paint, and dust from clogging the velocity-reduction screen. During discharge, internal pressure pops the cap off instantly. Missing or debris-laden caps must be replaced at every semi-annual inspection.\u003c\/p\u003e\n      \u003ch3\u003eScreen Integrity Audit\u003c\/h3\u003e\n      \u003cp\u003eThe internal stainless steel screen must be checked for corrosion or hardened chemical deposits during each NFPA 17 inspection. A clogged screen restricts flow and disrupts the hydraulic balance of the entire manifold, potentially leaving hazards unprotected.\u003c\/p\u003e\n      \u003ch3\u003ePlating and Thread Verification\u003c\/h3\u003e\n      \u003cp\u003eInspect the nickel-chrome plating and 3\/8\" NPT threads for pitting caused by solvent vapors, particularly in paint booth installations. Structural thread failure can cause the nozzle to separate from the pipe during a discharge event.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eWhy is the 83-844258-000 plated in nickel-chrome?\u003c\/h3\u003e\n      \u003cp\u003eNickel-chrome plated brass provides superior resistance to the caustic vapors found near dip tanks compared to standard brass. This ensures the nozzle remains clean and the orifice dimensions stay precise over a 10-year service life in aggressive industrial environments.\u003c\/p\u003e\n      \u003ch3\u003eCan this nozzle be used with the Badger Range Guard wet chemical system?\u003c\/h3\u003e\n      \u003cp\u003eNo. The 83-844258-000 is calibrated for dry chemical agents. Using it in a wet chemical system will result in an immediate clog due to the difference in fluid viscosity between the two agent types.\u003c\/p\u003e\n      \u003ch3\u003eWhat happens if I install this nozzle without the internal screen?\u003c\/h3\u003e\n      \u003cp\u003eWithout the velocity-reduction screen, discharge velocity would be high enough to splash burning liquid out of the tank, spreading the fire. The nozzle would no longer function as a low overhead unit and the UL\/FM safety listing would be voided.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  document.querySelectorAll('.accordion-header').forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Kidde-Fenwal \/ Badger 83-844258-000 Low Overhead Nozzle | 3\/8\\\" NPT | 2 Flow Points\",\n  \"description\": \"UL Listed and FM Approved low overhead dry chemical local application nozzle for dip tank, quench tank, and paint booth fire suppression. 3\/8\\\" NPT female inlet, nickel-chrome plated brass body, stainless steel internal velocity-reduction screen for soft-landing discharge. 2 flow point rating for balanced Kidde-Fenwal and Badger manifold hydraulics. Compatible with ABC, BC, and Purple-K agents. Requires 83-259100-000 blow-off cap. NFPA 17 compliant.\",\n  \"sku\": \"83-844258-000\",\n  \"mpn\": \"83-844258-000\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"Kidde-Fenwal\" },\n  \"manufacturer\": { \"@type\": \"Organization\", \"name\": \"Badger Fire Protection \/ Kidde-Fenwal\" },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    { \"@type\": \"PropertyValue\", \"name\": \"Nozzle Style\", \"value\": \"Low Overhead, Local Application\" },\n    { \"@type\": \"PropertyValue\", \"name\": \"Inlet Thread\", \"value\": \"3\/8 inch NPT Female\" },\n    { \"@type\": \"PropertyValue\", \"name\": \"Body Material\", \"value\": \"Nickel-chrome plated brass\" },\n    { \"@type\": \"PropertyValue\", \"name\": \"Flow Point Rating\", \"value\": \"2 Flow Points\" },\n    { \"@type\": \"PropertyValue\", \"name\": \"Internal Component\", \"value\": \"Stainless steel velocity-reduction screen\" },\n    { \"@type\": \"PropertyValue\", \"name\": \"Certifications\", \"value\": \"UL Listed, FM Approved\" }\n  ]\n}\n\u003c\/script\u003e\n\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":47356846506149,"sku":null,"price":184.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/BadgerIndustryGuardLowOverheadNozzle_SingleItem-83-844258-000_d2eacdd9-a9d9-41e4-a3fe-c67844c3d9e1.webp?v=1771286484"}],"url":"https:\/\/profireandsafety.com\/collections\/badger-industry-guard-nozzles.oembed","provider":"Pro Fire and Safety","version":"1.0","type":"link"}