{"title":"Badger Industry Guard Pull Stations","description":"","products":[{"product_id":"range-guard-remote-manual-release-combination-rg120110","title":"Range Guard Remote Manual Release Combination 120110","description":"\u003cbody\u003e\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eRange Guard Combination Remote Manual Release | 120110 | For Range Guard and Industry Guard Systems\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section{max-width:100%;margin:2rem 0;font-family:Arial,sans-serif;color:#333}.accordion-item{border-bottom:1px solid #ddd}.accordion-header{display:flex;justify-content:space-between;padding:2rem 0;cursor:pointer;background:none;border:none;width:100%;text-align:left;color:#333}.accordion-header:hover,.accordion-header:focus{color:#333;background:none;outline:none}.accordion-title{font-size:1.5rem;font-weight:500}.accordion-icon{font-size:1.5rem}.accordion-item.active .accordion-icon{transform:rotate(180deg)}.accordion-content{max-height:0;overflow:hidden}.accordion-item.active .accordion-content{max-height:none}.accordion-content-inner{font-size:1.4rem;line-height:1.7;color:#555;padding-bottom:2rem}.accordion-content-inner p{margin:0 0 1rem 0}.accordion-content-inner ul{margin:0 0 1rem 0;padding-left:2rem}.accordion-content-inner li{margin-bottom:.4rem}.accordion-content-inner h3{font-size:1.4rem;font-weight:600;color:#333;margin:1.5rem 0 .5rem 0}.specs-table{width:100%;border-collapse:collapse}.specs-table th,.specs-table td{border:1px solid #ddd;padding:.75rem 1rem;font-size:1.4rem;text-align:left}.specs-table th{background-color:#f5f5f5;font-weight:600;color:#333}\n\u003c\/style\u003e\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Range Guard Combination Remote Manual Release (P\/N 120110, full part number 60-120110-001) is the manual activation pull station for Range Guard and Industry Guard kitchen fire suppression systems. It is installed at a point of egress, allowing kitchen staff to manually trigger a full system discharge from a safe distance without having to reach the control head directly.\u003c\/p\u003e\n      \u003cp\u003eThe \"combination\" in the name refers to this station's dual actuation capability: it functions as both a pull-to-trip and a release-to-trip device, meaning it is compatible with both the UCH (Universal Control Head) and the older A-plus control head systems. This makes it the standard pull station for current Range Guard installations. The unit includes stainless steel cable pre-connected within a housing assembly, integrating the pull ring mechanism and cable routing into a single compact unit that mounts at the egress point and connects back to the control head through the system's detection cable run.\u003c\/p\u003e\n      \u003cp\u003eWhen staff pull the ring or trip the release on this station, the cable relaxes tension at the control head, actuating the system the same way an automatic fusible link separation would. This gives kitchen personnel a reliable manual override that works even if a fire is spotted before heat at the fusible link location would trigger an automatic discharge.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBadger Fire Protection (Kidde-Fenwal)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e120110 (60-120110-001)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eCombination Remote Manual Release (Pull-to-Trip and Release-to-Trip)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003eStainless Steel (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eRange Guard (UCH and A-plus Control Heads) and Industry Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003ePoint of Egress, Height per Authority Having Jurisdiction\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eInstallation and Compliance\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eRange Guard systems are pre-engineered systems under NFPA 17A and NFPA 96. Pull station installation must be performed by a certified Range Guard distributor.\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eEgress Location:\u003c\/strong\u003e NFPA 17A and NFPA 96 require a remote manual pull station at a point of egress so that staff activating the system can exit the kitchen immediately after pulling the station. Mount at a height set by the Authority Having Jurisdiction.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMonthly Visual Inspection:\u003c\/strong\u003e Confirm the pull ring is intact, the housing is unobstructed, and any tamper seal or pull tab is in place as part of the monthly visual inspection.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eSemiannual Professional Service:\u003c\/strong\u003e A qualified technician tests the pull station by manually actuating the system per the manufacturer's procedure and verifies correct cable tension throughout the run.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePost-Discharge Inspection:\u003c\/strong\u003e After any system actuation, the pull station and full detection cable network must be inspected, reset, and recertified before the system returns to service.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eWhat does \"combination\" mean in the product name?\u003c\/h3\u003e\n      \u003cp\u003eThis pull station supports both pull-to-trip and release-to-trip actuation, making it compatible with both the current UCH (Universal Control Head) and the older A-plus control head. This combination design eliminates the need to stock two separate pull stations for the two control head types.\u003c\/p\u003e\n      \u003ch3\u003eWhen should staff use the manual pull station instead of letting the system actuate automatically?\u003c\/h3\u003e\n      \u003cp\u003eStaff should pull the station any time they observe a fire in the kitchen and can safely reach the station without putting themselves at risk. The manual pull station provides immediate discharge without waiting for heat to reach a fusible link. During an evacuation, activating the pull station on the way out is standard practice.\u003c\/p\u003e\n      \u003ch3\u003eCan I install this myself?\u003c\/h3\u003e\n      \u003cp\u003eNo. Installation and cable tension setup must be performed by a certified Range Guard distributor. Incorrect cable tension can prevent the station from properly releasing the control head on activation, or can cause false actuations.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003edocument.addEventListener('DOMContentLoaded',function(){document.querySelectorAll('.accordion-header').forEach(h=\u003eh.addEventListener('click',function(){this.parentElement.classList.toggle('active')}))});\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"Product\",\"name\":\"Range Guard Combination Remote Manual Release | 120110 | For Range Guard and Industry Guard Systems\",\"description\":\"Combination remote manual pull station for Range Guard and Industry Guard kitchen fire suppression systems. Pull-to-trip and release-to-trip dual actuation compatible with UCH and A-plus control heads. Stainless steel cable included. Mounted at egress per NFPA 17A.\",\"sku\":\"120110\",\"mpn\":\"60-120110-001\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Range Guard\"},\"category\":\"Fire Suppression Equipment\"}\n\u003c\/script\u003e\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":45939145670821,"sku":null,"price":119.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/badger-default-title-range-guard-remote-manual-release-combination-120110-33353668919461_c1851b1c-da13-4e08-9998-8340e59be37f.webp?v=1771286711"},{"product_id":"rg875572-range-guard-wk-875572-900-manual-remote-release","title":"875572 Range Guard Manual Remote Release","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eRange Guard Manual Remote Release Pull Station | Part No. WK-875572-900\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n  .accordion-item { border-bottom: 1px solid #ddd; }\n  .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; color: #333; }\n  .accordion-header:hover, .accordion-header:focus { color: #333; background: none; outline: none; }\n  .accordion-title { font-size: 1.5rem; font-weight: 500; }\n  .accordion-icon { font-size: 1.5rem; }\n  .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n  .accordion-content { max-height: 0; overflow: hidden; }\n  .accordion-item.active .accordion-content { max-height: none; }\n  .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; padding-bottom: 2rem; }\n  .accordion-content-inner p { margin: 0 0 1rem 0; }\n  .accordion-content-inner ul { margin: 0 0 1rem 0; padding-left: 2rem; }\n  .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; color: #333; margin: 1.5rem 0 0.5rem 0; }\n  .specs-table { width: 100%; border-collapse: collapse; }\n  .specs-table th, .specs-table td { border: 1px solid #ddd; padding: 0.75rem 1rem; font-size: 1.4rem; text-align: left; }\n  .specs-table th { background-color: #f5f5f5; font-weight: 600; color: #333; }\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Range Guard WK-875572-900 Manual Remote Release is a fire suppression pull station assembly that allows remote manual activation of Range Guard kitchen fire suppression systems from a safe location outside the immediate fire hazard area. Includes cable housing and all mounting hardware for wall installation, providing a complete fire suppression system pull station solution for NFPA 96-compliant manual activation capability in commercial kitchen environments.\u003c\/p\u003e\n      \u003cp\u003eThe fire manual pull station is a critical life-safety component for any kitchen fire suppression system. NFPA 96 requires that a manual means of system activation be installed in the path of egress from the kitchen — so that staff can activate the Range Guard system while safely evacuating rather than requiring them to remain in the fire zone to initiate suppression. The WK-875572-900 provides that manual activation point, with cable housing that routes cleanly from the pull station location to the Range Guard universal control head or compatible release module.\u003c\/p\u003e\n      \u003cp\u003eFor fire protection contractors completing Range Guard system installations or replacing worn manual release hardware during service, the WK-875572-900 is the OEM fire suppression pull station for Range Guard systems. It is identified in the range guard installation manual as the approved manual activation component for the range guard system and must be installed per the range guard fire suppression system manual placement requirements to maintain UL 300 compliance. A pull station guard is available separately for installations where tamper protection is required.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRange Guard (Badger)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eWK-875572-900\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManual Remote Release \/ Fire Suppression Pull Station\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003ePull station assembly, cable housing, mounting hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eRange Guard kitchen fire suppression systems\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall installation, surface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed, NFPA 96 compliant, OEM Original\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance (NFPA 96)\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003ePlacement Requirements\u003c\/h3\u003e\n      \u003cp\u003ePer NFPA 96, the manual pull station must be located in the path of egress from the kitchen — accessible from the exit route without requiring the operator to pass through the fire hazard zone. Mount the WK-875572-900 at a height accessible to all kitchen staff, clearly identified with fire suppression pull station signage. The range guard installation manual specifies maximum cable lengths from the pull station to the control head — verify the routing distance is within the approved specification before finalizing the installation location.\u003c\/p\u003e\n      \u003ch3\u003eCable Routing\u003c\/h3\u003e\n      \u003cp\u003eRoute the cable housing from the pull station to the Range Guard control head per the range guard fire suppression system manual cable routing requirements. Avoid running cable through areas subject to damage from kitchen equipment, foot traffic, or heat. Secure the cable housing at regular intervals to prevent sag or movement. Verify cable tension and pull station release function during system commissioning.\u003c\/p\u003e\n      \u003ch3\u003eSemi-Annual Inspection\u003c\/h3\u003e\n      \u003cp\u003eDuring NFPA 17A and NFPA 96 semi-annual inspections, verify the pull station cable is intact, the release mechanism moves freely, and the pull station guard (if installed) is present and functional. Test the pull station release function using the Range Guard-specified test procedure without triggering a live system discharge. Document the test in the fire suppression system inspection record.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eIs a pull station guard required with the WK-875572-900?\u003c\/h3\u003e\n      \u003cp\u003eA pull station guard is required where accidental activation by unauthorized personnel is a concern — particularly in public-facing kitchen areas. The pull station guard accessory is available separately and mounts over the WK-875572-900 housing. In staff-only kitchen environments, a guard may not be required but is recommended as best practice to prevent nuisance activations.\u003c\/p\u003e\n      \u003ch3\u003eCan this pull station be used with Amerex or Pyro-Chem systems?\u003c\/h3\u003e\n      \u003cp\u003eNo. The WK-875572-900 is specifically designed and listed for Range Guard kitchen fire suppression systems and compatible Range Guard control heads. Amerex KP and Pyro-Chem systems use their own OEM fire suppression pull station hardware. Always match pull station hardware to the system manufacturer to maintain UL 300 compliance and ensure correct cable tension and release geometry.\u003c\/p\u003e\n      \u003ch3\u003eWhat is the maximum cable length for the pull station installation?\u003c\/h3\u003e\n      \u003cp\u003eThe maximum cable length is specified in the range guard installation manual for each system configuration. Exceeding the maximum cable length increases friction in the cable housing and can prevent a clean pull station release — potentially preventing system activation in an emergency. Verify the pull station location and cable routing length against the range guard fire suppression system manual before finalizing the installation.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  document.querySelectorAll('.accordion-header').forEach(h =\u003e h.addEventListener('click', function() { this.parentElement.classList.toggle('active'); }));\n});\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Range Guard Manual Remote Release Pull Station | Part No. WK-875572-900\",\n  \"description\": \"OEM Range Guard manual remote release fire suppression pull station. Complete assembly with cable housing and wall mounting hardware. NFPA 96 compliant manual activation in kitchen egress path. Semi-annual inspection required per NFPA 17A. Pull station guard available separately. Not compatible with Amerex or Pyro-Chem systems.\",\n  \"sku\": \"WK-875572-900\", \"mpn\": \"875572\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"Range Guard\" },\n  \"category\": \"Fire Suppression Equipment\"\n}\n\u003c\/script\u003e\n\n\u003c\/body\u003e","brand":"Badger","offers":[{"title":"Default Title","offer_id":45957811503269,"sku":"875572","price":85.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/badger-default-title-875572-range-guard-manual-remote-release-33394342232229_1f9b497c-91aa-48fa-8f1a-1d42f76ae6fd.webp?v=1771286598"}],"url":"https:\/\/profireandsafety.com\/collections\/badger-industry-guard-pull-stations.oembed","provider":"Pro Fire and Safety","version":"1.0","type":"link"}