{"title":"Pyro-Chem Monarch Pull Stations","description":"","products":[{"product_id":"pyrochem-pull-station-rps-m-551074","title":"Pyro-Chem Pull Station RPS-M - 551074","description":"\u003cdiv class=\"product-section\"\u003e\n  \u003cstyle\u003e\n    .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n    .accordion-item { border-bottom: 1px solid #ddd; }\n    .accordion-item:first-child { border-top: 1px solid #ddd; }\n    .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; }\n    .accordion-title { font-size: 1.5rem; font-weight: 500; margin: 0; }\n    .accordion-icon { font-size: 1.5rem; }\n    .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n    .accordion-content { max-height: 0; overflow: hidden; }\n    .accordion-item.active .accordion-content { max-height: none; padding-bottom: 1.5rem; }\n    .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; }\n    .accordion-content-inner p { margin: 0 0 1.5rem 0; }\n    .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; margin: 1.5rem 0 1rem 0; }\n    .accordion-content-inner ul { margin: 1rem 0 1.5rem 0; padding-left: 2rem; }\n    .accordion-content-inner li { margin-bottom: 0.75rem; font-size: 1.4rem; }\n    .specs-table { width: 100%; border-collapse: collapse; margin: 1.5rem 0 0 0; }\n    .specs-table tr { border-bottom: 1px solid #ddd; }\n    .specs-table td { padding: 1rem 0; font-size: 1.4rem; }\n    .specs-table td:first-child { font-weight: 600; width: 40%; padding-right: 2rem; }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"accordion\"\u003e\n    \u003c!-- Product Overview --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eProduct Overview\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eThe Pyro-Chem RPS-M Pull Station (551074) is a critical manual override component designed for industrial and commercial fire suppression systems. While automatic detection via fusible links is the primary defense, the RPS-M provides the essential human element, allowing personnel to manually trigger the discharge of extinguishing agents the moment a fire is sighted. In the chaotic seconds of a kitchen flare-up, this device acts as the high-visibility bridge between human observation and mechanical suppression.\u003c\/p\u003e\n          \n          \u003cp\u003eBuilt for durability in high-heat environments, this manual remote pull station uses a rugged mechanical cable linkage. This design ensures the system remains functional even during total power failures, as it does not rely on electrical circuits to actuate the suppression cylinders. It is a staple in professional kitchen fire safety, specifically engineered to integrate seamlessly with the Kitchen Knight II system.\u003c\/p\u003e\n\n          \u003ch3\u003eThe Science of Actuation: Mechanical Stroke and Cable Tension\u003c\/h3\u003e\n          \n          \u003cp\u003e\u003cstrong\u003eMechanical Stroke Calibration\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eThe RPS-M is engineered with a specific throw or mechanical stroke. When the handle is pulled, it retracts the internal stainless steel cable by a precise distance. This displacement is mathematically matched to the control head release sear, ensuring that a single, fluid motion is sufficient to puncture the agent cylinder.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eTension-Loss Logic\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eUnlike electrical switches that make a circuit, the RPS-M works in conjunction with a detection line tensioner. In some configurations, the pull station introduces a tension drop that simulates the melting of a fusible link, triggering a reliable response from the mechanical control head.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eHigh-Stress Component Integrity\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eThe internal pulleys and bushings within the 551074 housing are manufactured to minimize cable friction. This ensures that the force applied by the user is transmitted directly to the suppression system without binding or cable stretch, a vital metric in manual pull station engineering.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Applications \u0026 Use Cases --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCommercial Cooking Lines:\u003c\/strong\u003e Providing a manual override for fryer batteries and charbroiler stations.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eInstitutional Cafeterias:\u003c\/strong\u003e Essential for schools and hospitals where staff require a simple, intuitive fire activation interface.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Catering Units:\u003c\/strong\u003e Ensuring safety in fast-paced environments where manual override accessibility is a code requirement.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eModular Kitchen Units:\u003c\/strong\u003e A compact, wall-mounted solution that can handle the vibration and space constraints of mobile food service.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eIndustrial Spray Booths:\u003c\/strong\u003e Acting as a remote trigger for dry chemical systems in hazardous coating environments.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Technical Specifications --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eTechnical Specifications\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003ctable class=\"specs-table\"\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eManufacturer\u003c\/td\u003e\n                \u003ctd\u003ePyro-Chem (A Johnson Controls Brand)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003ePart Number\u003c\/td\u003e\n                \u003ctd\u003e551074 (Model RPS-M)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eActivation Type\u003c\/td\u003e\n                \u003ctd\u003eManual Mechanical Pull\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eMounting\u003c\/td\u003e\n                \u003ctd\u003eSurface or Wall Mount\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eCompatibility\u003c\/td\u003e\n                \u003ctd\u003eKitchen Knight II \u0026amp; Pyro-Chem Series\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eConnection Type\u003c\/td\u003e\n                \u003ctd\u003eMechanical Steel Cable\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eHandle Finish\u003c\/td\u003e\n                \u003ctd\u003eHigh-Visibility Safety Red\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Compliance \u0026 Safety --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eTo maintain NFPA 17A and NFPA 96 compliance, the installation of the RPS-M must follow strict professional protocols:\u003c\/p\u003e\n\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eEgress Route Placement:\u003c\/strong\u003e Per NFPA guidelines, pull stations should be located along a path of egress, typically between 10 and 20 feet from the protected appliances. This ensures the operator is moving away from the fire during activation.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHeight Requirements:\u003c\/strong\u003e The station must be mounted at a height (usually 42 to 48 inches) that is easily accessible to all staff members, following ADA-compliant fire safety standards.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e The mechanical cable must be routed through EMT conduit or specialized corner pulleys to prevent kinking. A bent cable can increase the pull-force required, potentially delaying activation during a kitchen emergency.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eSemi-Annual Inspection:\u003c\/strong\u003e During the mandatory 6-month check, a certified fire technician must perform a live pull (with the cylinders disconnected) to ensure the handle moves freely and the cable triggers the control head sear instantly.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- FAQ --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eFAQ\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003e\u003cstrong\u003eDoes the RPS-M 551074 require a battery?\u003c\/strong\u003e\u003cbr\u003e\n          No. The RPS-M is a purely mechanical device. It triggers the system by pulling a physical cable, making it immune to electrical outages. This provides a fail-safe manual override that does not require maintenance of electrical circuits.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eCan this pull station be used with Ansul systems?\u003c\/strong\u003e\u003cbr\u003e\n          No. While they look similar, the internal stroke and tension requirements of the 551074 are specifically calibrated for Pyro-Chem OEM systems. Using mismatched components can lead to a short-pull failure, which is a major system failure liability.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eWhat is the difference between an M and an E pull station?\u003c\/strong\u003e\u003cbr\u003e\n          The M stands for Mechanical, meaning it uses a physical cable. An E (Electric) station uses a contact switch to send a signal to a solenoid. The RPS-M 551074 is the preferred choice for facilities that prioritize non-electric fire safety and reliability.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cscript\u003e\n    document.addEventListener('DOMContentLoaded', function() {\n      const headers = document.querySelectorAll('.accordion-header');\n      headers.forEach(header =\u003e {\n        header.addEventListener('click', function() {\n          this.parentElement.classList.toggle('active');\n        });\n      });\n    });\n  \u003c\/script\u003e\n\n  \u003cscript type=\"application\/ld+json\"\u003e\n  {\n    \"@context\": \"https:\/\/schema.org\/\",\n    \"@type\": \"Product\",\n    \"name\": \"Pyro-Chem RPS-M Pull Station - Part No. 551074 - Manual Remote Activation\",\n    \"description\": \"Critical manual override component for industrial and commercial fire suppression systems with mechanical cable linkage for power-independent reliability\",\n    \"sku\": \"551074\",\n    \"mpn\": \"RPS-M\",\n    \"brand\": {\n      \"@type\": \"Brand\",\n      \"name\": \"Pyro-Chem\"\n    },\n    \"manufacturer\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Pyro-Chem (A Johnson Controls Brand)\"\n    },\n    \"additionalProperty\": [\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Activation Type\",\n        \"value\": \"Manual Mechanical Pull\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Mounting\",\n        \"value\": \"Surface or Wall Mount\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Compatibility\",\n        \"value\": \"Kitchen Knight II \u0026 Pyro-Chem Series\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Connection Type\",\n        \"value\": \"Mechanical Steel Cable\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Handle Finish\",\n        \"value\": \"High-Visibility Safety Red\"\n      }\n    ],\n    \"category\": \"Fire Suppression Equipment\"\n  }\n  \u003c\/script\u003e\n\u003c\/div\u003e","brand":"PyroChem","offers":[{"title":"Default Title","offer_id":45948705898661,"sku":"551074","price":105.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/pyrochem-default-title-pyro-chem-pull-station-rps-m-551074-33373567287461_e9cb8bc0-2ff1-47bf-aca0-2bda8fe8a7ed.webp?v=1771286612"},{"product_id":"pyro-chem-double-action-pull-station-551166","title":"Pyro-Chem Double Action Pull Station - 551166","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003ePyro-Chem RPS-E2 Double Action Pull Station | Part No. 551166 | Electrical Series\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Pyro-Chem Double Action Pull Station (551166), designated as Model RPS-E2, is a mission-critical manual command station engineered for the Kitchen Knight II and Monarch industrial fire suppression systems. In the sophisticated architecture of fire safety, the RPS-E2 serves as the human fail-safe. While automatic detection systems rely on thermal fusible links or electronic sensors, the RPS-E2 allows on-site personnel to initiate a full suppression discharge instantly from a safe distance, such as a designated point of egress.\u003c\/p\u003e\n        \u003cp\u003eDesigned for high-traffic and high-vibration industrial environments, the 551166 utilizes a double-action mechanical gate. By requiring two distinct physical movements to actuate, the RPS-E2 virtually eliminates the risk of accidental triggering. For facility managers, the RPS-E2 is more than a pull station; it is a rugged manual override interface designed to protect against costly system downtime.\u003c\/p\u003e\n\n        \u003ch3\u003eTactile Intentionality\u003c\/h3\u003e\n        \u003cp\u003eIn a standard single-action station, a single snag of a cleaning cloth can trigger a discharge. The RPS-E2 requires push-and-pull mechanics, a push in of the front plate followed by a pull down of the handle. This mechanical sequence ensures that actuation is a result of deliberate human intent, providing essential nuisance trip mitigation.\u003c\/p\u003e\n\n        \u003ch3\u003eDie-Cast Structural Integrity\u003c\/h3\u003e\n        \u003cp\u003eUnlike consumer-grade plastic units, the 551166 is constructed from a heavy-duty, corrosion-resistant die-cast metal alloy. This is critical in environments where aerosolized grease and caustic cleaning chemicals can degrade plastic over time. The metal housing ensures the hinges and switch mechanisms remain viable for the entire service life of the system.\u003c\/p\u003e\n\n        \u003ch3\u003eHigh-Visibility Fire Red Finishing\u003c\/h3\u003e\n        \u003cp\u003eThe unit is finished with a high-impact, oven-cured fire red powder coat. This ensures the station remains visible through thick smoke or during power failures, guiding personnel to the manual release point when seconds count.\u003c\/p\u003e\n\n        \u003ch3\u003eSPST Switch Architecture\u003c\/h3\u003e\n        \u003cp\u003eThe unit features a high-reliability single pole single throw (SPST) switch. When the handle is pulled, the switch completes the circuit, sending a low-voltage signal to the Electric Control Head (ECH3) or the system's main control panel.\u003c\/p\u003e\n\n        \u003ch3\u003eSupervised Circuitry Dynamics\u003c\/h3\u003e\n        \u003cp\u003eIn a professional installation, the RPS-E2 is typically wired with an end-of-line resistor (EOLR). The control panel constantly monitors the circuit for continuity. If the wiring is cut or the station is tampered with, the resistance changes and the panel triggers a trouble signal, ensuring the system does not sit in a dead state.\u003c\/p\u003e\n\n        \u003ch3\u003eECH Coordination\u003c\/h3\u003e\n        \u003cp\u003eUpon receiving the signal from the 551166, the Electric Control Head triggers a pneumatic actuation cartridge. This pulse travels through the manifold to the agent cylinders, initiating a total discharge. This electrical setup is ideal for complex layouts where routing mechanical cables around multiple corners would be impossible.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Applications \u0026 Use Cases --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Commercial Kitchens:\u003c\/strong\u003e Positioned near exits to serve as the chef's final fail-safe for the Kitchen Knight II system.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eIndustrial Paint Spray Booths:\u003c\/strong\u003e The electrical nature of the RPS-E2 allows it to be placed outside the hazardous vapor zone of a Monarch system.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHazardous Material Storage:\u003c\/strong\u003e Providing a rugged, vibration-resistant manual trigger for chemical lockers where accidental release would be catastrophic.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstitutional Facilities:\u003c\/strong\u003e Protecting massive cooking lines where manual activation points must be networked across large distances.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRetrofit Modernization:\u003c\/strong\u003e Upgrading older mechanical pull systems to electrical supervision to meet modern building codes.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003ePyro-Chem (A Johnson Controls Brand)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e551166 (Model RPS-E2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eAction Type\u003c\/td\u003e\n              \u003ctd\u003eDual-Action Pull Station\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSwitch Configuration\u003c\/td\u003e\n              \u003ctd\u003eSingle Pole Single Throw (SPST)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eConstruction\u003c\/td\u003e\n              \u003ctd\u003eHeavy-Duty Die-Cast Metal\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFinish\u003c\/td\u003e\n              \u003ctd\u003eFire Red Powder Coat\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompatibility\u003c\/td\u003e\n              \u003ctd\u003eKitchen Knight II \/ Monarch Series\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompliance\u003c\/td\u003e\n              \u003ctd\u003eUL Listed, FM Approved, CSFM Listed\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: Installation \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eThe 6-Month Functional Audit\u003c\/h3\u003e\n        \u003cp\u003eEvery six months, a technician must perform a functional test. Using a silent test mode, the technician ensures the SPST switch sends the correct signal without firing the agent cylinders.\u003c\/p\u003e\n\n        \u003ch3\u003ePath of Egress Accessibility\u003c\/h3\u003e\n        \u003cp\u003eNFPA standards mandate that the 551166 be unobstructed and located along the natural path of exit. If a remodel has moved the exit, the path of egress accessibility must be re-verified.\u003c\/p\u003e\n\n        \u003ch3\u003eTamper Seal Verification\u003c\/h3\u003e\n        \u003cp\u003eMost jurisdictions require a visual tamper indicator (break-tie). During maintenance, technicians replace these seals to provide the Fire Marshal with proof that the system remains untampered.\u003c\/p\u003e\n\n        \u003ch3\u003eADA Mounting Heights\u003c\/h3\u003e\n        \u003cp\u003eTo ensure accessibility, the RPS-E2 should be mounted between 42 to 48 inches from the floor. The unit fits a standard 2x4 electrical backbox, or a specific red metal backbox for surface-mounted industrial applications.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 5: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan I use the RPS-E2 with an Ansul R-102 system?\u003c\/h3\u003e\n        \u003cp\u003eNo. While both brands are owned by Johnson Controls, the RPS-E2 is specifically listed for Pyro-Chem hardware. Mixing manufacturers is a significant code violation and will void your UL listing.\u003c\/p\u003e\n\n        \u003ch3\u003eWhat is the difference between single and double action?\u003c\/h3\u003e\n        \u003cp\u003eA single-action station is pull only. A dual-action pull station like the 551166 requires two steps (push then pull). This second step is the industry's primary defense against expensive accidental discharges in busy work zones.\u003c\/p\u003e\n\n        \u003ch3\u003eDoes the station come with a backbox?\u003c\/h3\u003e\n        \u003cp\u003eThe 551166 fits a standard 2x4 electrical backbox. For surface-mounted industrial applications, a specific red metal backbox is often used to maintain the die-cast structural integrity and aesthetic.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Pyro-Chem RPS-E2 Double Action Pull Station\",\n  \"description\": \"UL Listed dual-action electrical pull station for Pyro-Chem Kitchen Knight II and Monarch fire suppression systems. Heavy-duty die-cast metal with fire red powder coat finish. SPST switch for supervised low-voltage signal to Electric Control Head (ECH3). Requires push-then-pull actuation for nuisance trip mitigation. Mounts to standard 2x4 electrical backbox. FM Approved, CSFM Listed.\",\n  \"sku\": \"551166\",\n  \"mpn\": \"551166\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Pyro-Chem\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Pyro-Chem (A Johnson Controls Brand)\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Part Number\",\n      \"value\": \"551166 (Model RPS-E2)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Action Type\",\n      \"value\": \"Dual-Action Pull Station\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Switch Configuration\",\n      \"value\": \"Single Pole Single Throw (SPST)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Construction\",\n      \"value\": \"Heavy-Duty Die-Cast Metal\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Finish\",\n      \"value\": \"Fire Red Powder Coat\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compatibility\",\n      \"value\": \"Kitchen Knight II \/ Monarch Series\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compliance\",\n      \"value\": \"UL Listed, FM Approved, CSFM Listed\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"PyroChem","offers":[{"title":"Default Title","offer_id":47487226347685,"sku":null,"price":107.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/Pyro-ChemDoubleActionPullStation-551166_eda8f9ef-3662-4bac-9e4f-1fe7f815b7f0.webp?v=1771286423"}],"url":"https:\/\/profireandsafety.com\/collections\/pyro-chem-monarch-pull-stations.oembed","provider":"Pro Fire and Safety","version":"1.0","type":"link"}