{"title":"System Components: Pull Stations","description":"","products":[{"product_id":"rps-m-buckeye-pull-station","title":"RPS-M Buckeye Pull Station","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eBuckeye RPS-M Manual Pull Station | Kitchen Fire Suppression\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n  .accordion-item { border-bottom: 1px solid #ddd; }\n  .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; color: #333; }\n  .accordion-header:hover, .accordion-header:focus { color: #333; background: none; outline: none; }\n  .accordion-title { font-size: 1.5rem; font-weight: 500; }\n  .accordion-icon { font-size: 1.5rem; }\n  .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n  .accordion-content { max-height: 0; overflow: hidden; }\n  .accordion-item.active .accordion-content { max-height: none; }\n  .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; padding-bottom: 2rem; }\n  .accordion-content-inner p { margin: 0 0 1rem 0; }\n  .accordion-content-inner ul { margin: 0 0 1rem 0; padding-left: 2rem; }\n  .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; color: #333; margin: 1.5rem 0 0.5rem 0; }\n  .specs-table { width: 100%; border-collapse: collapse; }\n  .specs-table th, .specs-table td { border: 1px solid #ddd; padding: 0.75rem 1rem; font-size: 1.4rem; text-align: left; }\n  .specs-table th { background-color: #f5f5f5; font-weight: 600; color: #333; }\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Buckeye RPS-M is a manual pull station specifically engineered for Buckeye kitchen fire suppression systems, providing reliable mechanical activation of the suppression system from a safe location in the kitchen egress path. When kitchen staff observe a fire on the protected cooking equipment before the automatic thermal detection line has activated, the RPS-M allows immediate manual system discharge — delivering the critical seconds of early response that can prevent a small cooking fire from escalating into a full commercial kitchen emergency.\u003c\/p\u003e\n      \u003cp\u003eThe RPS-M is part of the Buckeye Kitchen Mister (BFR) fire suppression system ecosystem — a complete line of buckeye fire suppression system components designed and listed for commercial kitchen wet chemical suppression. As a fire suppression pull station, the RPS-M must be installed in the egress path per NFPA 96 and the buckeye kitchen fire suppression system manual, ensuring kitchen personnel can activate the system while evacuating rather than remaining in the fire hazard zone. The pull station guard accessory is available separately for installations where tamper protection is required.\u003c\/p\u003e\n      \u003cp\u003eFor fire protection contractors installing or servicing Buckeye kitchen fire suppression systems, the RPS-M is the OEM fire suppression pull station for Buckeye BFR configurations. It is a standard buckeye parts item available through authorized buckeye fire distributors. Like all Buckeye kitchen fire suppression system components, the RPS-M must be inspected semi-annually per NFPA 17A and NFPA 96 — verify the cable is intact, the release mechanism moves freely, and the unit is properly identified with fire suppression pull station signage at each service visit.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBuckeye Fire Equipment Company\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRPS-M\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eManual Pull Station\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eBuckeye Kitchen Mister (BFR) fire suppression systems\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall installation in egress path\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed, NFPA 96 compliant, OEM Original\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance (NFPA 96)\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003ePlacement Requirements\u003c\/h3\u003e\n      \u003cp\u003ePer NFPA 96, the RPS-M fire suppression pull station must be located in the path of egress from the kitchen — accessible while evacuating, not requiring the operator to pass through the fire hazard zone to reach it. Mount at a height accessible to all kitchen staff and clearly identify with fire suppression system pull station signage. Verify the cable routing distance from the RPS-M to the Buckeye control head is within the maximum length specified in the buckeye kitchen fire suppression system manual.\u003c\/p\u003e\n      \u003ch3\u003eSemi-Annual Inspection\u003c\/h3\u003e\n      \u003cp\u003eInspect the RPS-M at every semi-annual NFPA 17A and NFPA 96 service visit. Verify the cable is intact and free of kinks or abrasion damage, the pull station housing is undamaged, and the release mechanism cycles freely during a simulated test per the buckeye kitchen mister manual procedure. A pull station that binds or fails to release cleanly is an immediate red-tag deficiency. Document in the fire suppression system inspection record.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eIs the RPS-M compatible with Amerex or Pyro-Chem systems?\u003c\/h3\u003e\n      \u003cp\u003eNo. The RPS-M is specifically designed and listed for Buckeye Kitchen Mister fire suppression systems. Amerex KP systems use the Amerex 21481 pull station, and Pyro-Chem systems use their own OEM fire suppression pull station hardware. Cross-brand pull station substitution voids the UL 300 system listing — always match the pull station to the system manufacturer. Buckeye fire suppression system components are available through authorized buckeye fire distributors.\u003c\/p\u003e\n      \u003ch3\u003eWhere can I find Buckeye system documentation?\u003c\/h3\u003e\n      \u003cp\u003eThe buckeye kitchen fire suppression system manual, buckeye kitchen mister manual, and buckeye fire suppression system manual are available through authorized buckeye fire distributors and the Buckeye Fire Equipment Company documentation library. The buckeye nozzle chart and buckeye fire equipment catalog provide complete system design specifications for all BFR configurations.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  document.querySelectorAll('.accordion-header').forEach(h =\u003e h.addEventListener('click', function() { this.parentElement.classList.toggle('active'); }));\n});\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Buckeye RPS-M Manual Pull Station | Kitchen Fire Suppression\",\n  \"description\": \"UL Listed Buckeye RPS-M manual pull station for Buckeye Kitchen Mister BFR fire suppression systems. NFPA 96 compliant placement in kitchen egress path. Semi-annual inspection per NFPA 17A. Not compatible with Amerex or Pyro-Chem systems.\",\n  \"mpn\": \"RPS-M\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"Buckeye\" },\n  \"manufacturer\": { \"@type\": \"Organization\", \"name\": \"Buckeye Fire Equipment Company\" },\n  \"category\": \"Fire Suppression Equipment\"\n}\n\u003c\/script\u003e\n\n\u003c\/body\u003e","brand":"Buckeye","offers":[{"title":"Default Title","offer_id":45948477472933,"sku":"RPS-M","price":101.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/buckeye-default-title-rps-m-buckeye-pull-station-33372923822245_cb3f4994-0cac-47b3-a961-7fc90f96d563.webp?v=1771286641"},{"product_id":"pyrochem-pull-station-rps-m-551074","title":"Pyro-Chem Pull Station RPS-M - 551074","description":"\u003cdiv class=\"product-section\"\u003e\n  \u003cstyle\u003e\n    .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n    .accordion-item { border-bottom: 1px solid #ddd; }\n    .accordion-item:first-child { border-top: 1px solid #ddd; }\n    .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; }\n    .accordion-title { font-size: 1.5rem; font-weight: 500; margin: 0; }\n    .accordion-icon { font-size: 1.5rem; }\n    .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n    .accordion-content { max-height: 0; overflow: hidden; }\n    .accordion-item.active .accordion-content { max-height: none; padding-bottom: 1.5rem; }\n    .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; }\n    .accordion-content-inner p { margin: 0 0 1.5rem 0; }\n    .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; margin: 1.5rem 0 1rem 0; }\n    .accordion-content-inner ul { margin: 1rem 0 1.5rem 0; padding-left: 2rem; }\n    .accordion-content-inner li { margin-bottom: 0.75rem; font-size: 1.4rem; }\n    .specs-table { width: 100%; border-collapse: collapse; margin: 1.5rem 0 0 0; }\n    .specs-table tr { border-bottom: 1px solid #ddd; }\n    .specs-table td { padding: 1rem 0; font-size: 1.4rem; }\n    .specs-table td:first-child { font-weight: 600; width: 40%; padding-right: 2rem; }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"accordion\"\u003e\n    \u003c!-- Product Overview --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eProduct Overview\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eThe Pyro-Chem RPS-M Pull Station (551074) is a critical manual override component designed for industrial and commercial fire suppression systems. While automatic detection via fusible links is the primary defense, the RPS-M provides the essential human element, allowing personnel to manually trigger the discharge of extinguishing agents the moment a fire is sighted. In the chaotic seconds of a kitchen flare-up, this device acts as the high-visibility bridge between human observation and mechanical suppression.\u003c\/p\u003e\n          \n          \u003cp\u003eBuilt for durability in high-heat environments, this manual remote pull station uses a rugged mechanical cable linkage. This design ensures the system remains functional even during total power failures, as it does not rely on electrical circuits to actuate the suppression cylinders. It is a staple in professional kitchen fire safety, specifically engineered to integrate seamlessly with the Kitchen Knight II system.\u003c\/p\u003e\n\n          \u003ch3\u003eThe Science of Actuation: Mechanical Stroke and Cable Tension\u003c\/h3\u003e\n          \n          \u003cp\u003e\u003cstrong\u003eMechanical Stroke Calibration\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eThe RPS-M is engineered with a specific throw or mechanical stroke. When the handle is pulled, it retracts the internal stainless steel cable by a precise distance. This displacement is mathematically matched to the control head release sear, ensuring that a single, fluid motion is sufficient to puncture the agent cylinder.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eTension-Loss Logic\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eUnlike electrical switches that make a circuit, the RPS-M works in conjunction with a detection line tensioner. In some configurations, the pull station introduces a tension drop that simulates the melting of a fusible link, triggering a reliable response from the mechanical control head.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eHigh-Stress Component Integrity\u003c\/strong\u003e\u003c\/p\u003e\n          \u003cp\u003eThe internal pulleys and bushings within the 551074 housing are manufactured to minimize cable friction. This ensures that the force applied by the user is transmitted directly to the suppression system without binding or cable stretch, a vital metric in manual pull station engineering.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Applications \u0026 Use Cases --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCommercial Cooking Lines:\u003c\/strong\u003e Providing a manual override for fryer batteries and charbroiler stations.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eInstitutional Cafeterias:\u003c\/strong\u003e Essential for schools and hospitals where staff require a simple, intuitive fire activation interface.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Catering Units:\u003c\/strong\u003e Ensuring safety in fast-paced environments where manual override accessibility is a code requirement.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eModular Kitchen Units:\u003c\/strong\u003e A compact, wall-mounted solution that can handle the vibration and space constraints of mobile food service.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eIndustrial Spray Booths:\u003c\/strong\u003e Acting as a remote trigger for dry chemical systems in hazardous coating environments.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Technical Specifications --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eTechnical Specifications\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003ctable class=\"specs-table\"\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eManufacturer\u003c\/td\u003e\n                \u003ctd\u003ePyro-Chem (A Johnson Controls Brand)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003ePart Number\u003c\/td\u003e\n                \u003ctd\u003e551074 (Model RPS-M)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eActivation Type\u003c\/td\u003e\n                \u003ctd\u003eManual Mechanical Pull\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eMounting\u003c\/td\u003e\n                \u003ctd\u003eSurface or Wall Mount\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eCompatibility\u003c\/td\u003e\n                \u003ctd\u003eKitchen Knight II \u0026amp; Pyro-Chem Series\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eConnection Type\u003c\/td\u003e\n                \u003ctd\u003eMechanical Steel Cable\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eHandle Finish\u003c\/td\u003e\n                \u003ctd\u003eHigh-Visibility Safety Red\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Compliance \u0026 Safety --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eTo maintain NFPA 17A and NFPA 96 compliance, the installation of the RPS-M must follow strict professional protocols:\u003c\/p\u003e\n\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eEgress Route Placement:\u003c\/strong\u003e Per NFPA guidelines, pull stations should be located along a path of egress, typically between 10 and 20 feet from the protected appliances. This ensures the operator is moving away from the fire during activation.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eHeight Requirements:\u003c\/strong\u003e The station must be mounted at a height (usually 42 to 48 inches) that is easily accessible to all staff members, following ADA-compliant fire safety standards.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e The mechanical cable must be routed through EMT conduit or specialized corner pulleys to prevent kinking. A bent cable can increase the pull-force required, potentially delaying activation during a kitchen emergency.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eSemi-Annual Inspection:\u003c\/strong\u003e During the mandatory 6-month check, a certified fire technician must perform a live pull (with the cylinders disconnected) to ensure the handle moves freely and the cable triggers the control head sear instantly.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- FAQ --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eFAQ\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003e\u003cstrong\u003eDoes the RPS-M 551074 require a battery?\u003c\/strong\u003e\u003cbr\u003e\n          No. The RPS-M is a purely mechanical device. It triggers the system by pulling a physical cable, making it immune to electrical outages. This provides a fail-safe manual override that does not require maintenance of electrical circuits.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eCan this pull station be used with Ansul systems?\u003c\/strong\u003e\u003cbr\u003e\n          No. While they look similar, the internal stroke and tension requirements of the 551074 are specifically calibrated for Pyro-Chem OEM systems. Using mismatched components can lead to a short-pull failure, which is a major system failure liability.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eWhat is the difference between an M and an E pull station?\u003c\/strong\u003e\u003cbr\u003e\n          The M stands for Mechanical, meaning it uses a physical cable. An E (Electric) station uses a contact switch to send a signal to a solenoid. The RPS-M 551074 is the preferred choice for facilities that prioritize non-electric fire safety and reliability.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cscript\u003e\n    document.addEventListener('DOMContentLoaded', function() {\n      const headers = document.querySelectorAll('.accordion-header');\n      headers.forEach(header =\u003e {\n        header.addEventListener('click', function() {\n          this.parentElement.classList.toggle('active');\n        });\n      });\n    });\n  \u003c\/script\u003e\n\n  \u003cscript type=\"application\/ld+json\"\u003e\n  {\n    \"@context\": \"https:\/\/schema.org\/\",\n    \"@type\": \"Product\",\n    \"name\": \"Pyro-Chem RPS-M Pull Station - Part No. 551074 - Manual Remote Activation\",\n    \"description\": \"Critical manual override component for industrial and commercial fire suppression systems with mechanical cable linkage for power-independent reliability\",\n    \"sku\": \"551074\",\n    \"mpn\": \"RPS-M\",\n    \"brand\": {\n      \"@type\": \"Brand\",\n      \"name\": \"Pyro-Chem\"\n    },\n    \"manufacturer\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Pyro-Chem (A Johnson Controls Brand)\"\n    },\n    \"additionalProperty\": [\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Activation Type\",\n        \"value\": \"Manual Mechanical Pull\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Mounting\",\n        \"value\": \"Surface or Wall Mount\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Compatibility\",\n        \"value\": \"Kitchen Knight II \u0026 Pyro-Chem Series\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Connection Type\",\n        \"value\": \"Mechanical Steel Cable\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Handle Finish\",\n        \"value\": \"High-Visibility Safety Red\"\n      }\n    ],\n    \"category\": \"Fire Suppression Equipment\"\n  }\n  \u003c\/script\u003e\n\u003c\/div\u003e","brand":"PyroChem","offers":[{"title":"Default Title","offer_id":45948705898661,"sku":"551074","price":105.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/pyrochem-default-title-pyro-chem-pull-station-rps-m-551074-33373567287461_e9cb8bc0-2ff1-47bf-aca0-2bda8fe8a7ed.webp?v=1771286612"},{"product_id":"21481-amerex-kp-manual-pull-station","title":"21481 AMEREX KP MANUAL PULL STATION - OEM","description":"\u003cbody\u003e\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eAmerex 21481 KP Manual Pull Station | OEM | Kitchen Fire Suppression\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section { max-width: 100%; margin: 2rem 0; font-family: Arial, sans-serif; color: #333; }\n  .accordion-item { border-bottom: 1px solid #ddd; }\n  .accordion-header { display: flex; justify-content: space-between; padding: 2rem 0; cursor: pointer; background: none; border: none; width: 100%; text-align: left; color: #333; }\n  .accordion-header:hover, .accordion-header:focus { color: #333; background: none; outline: none; }\n  .accordion-title { font-size: 1.5rem; font-weight: 500; }\n  .accordion-icon { font-size: 1.5rem; }\n  .accordion-item.active .accordion-icon { transform: rotate(180deg); }\n  .accordion-content { max-height: 0; overflow: hidden; }\n  .accordion-item.active .accordion-content { max-height: none; }\n  .accordion-content-inner { font-size: 1.4rem; line-height: 1.7; color: #555; padding-bottom: 2rem; }\n  .accordion-content-inner p { margin: 0 0 1rem 0; }\n  .accordion-content-inner ul { margin: 0 0 1rem 0; padding-left: 2rem; }\n  .accordion-content-inner h3 { font-size: 1.4rem; font-weight: 600; color: #333; margin: 1.5rem 0 0.5rem 0; }\n  .specs-table { width: 100%; border-collapse: collapse; }\n  .specs-table th, .specs-table td { border: 1px solid #ddd; padding: 0.75rem 1rem; font-size: 1.4rem; text-align: left; }\n  .specs-table th { background-color: #f5f5f5; font-weight: 600; color: #333; }\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003cp\u003eThe Amerex 21481 is the OEM manual pull station for Amerex KP kitchen fire suppression systems. It delivers a reliable, dual-action manual activation method that allows kitchen staff or system operators to manually trigger a suppression discharge when a fire is detected before the automatic thermal detection line activates — or as an emergency override in any situation requiring immediate system discharge. The dual-action design requires two deliberate motions to activate, preventing accidental discharges from incidental contact in the busy commercial kitchen environment.\u003c\/p\u003e\n      \u003cp\u003eThe 21481 is designed for compatibility with Amerex MRM and PRM release modules and supports both surface and recessed mounting configurations, giving installation contractors flexibility to position the pull station at the most accessible and visible location per NFPA 96 manual activation requirements. As a fire suppression pull station, the 21481 must be installed within reach of the kitchen exit path so that staff can activate the system while evacuating — a specific NFPA 96 placement requirement for manual pull station fire suppression system installations.\u003c\/p\u003e\n      \u003cp\u003eA fire suppression system pull station is a critical life-safety component that bridges the gap between automatic thermal detection and human-initiated emergency response. In commercial kitchen environments where high-temperature cooking creates conditions that can overwhelm a fire before the thermal link melts, the ability to manually trigger the suppression system via the 21481 fire manual pull station can be the difference between a controlled suppression event and a catastrophic kitchen fire. It is a standard component on any fire suppression supply order for a complete Amerex KP system installation and is included in the pull station guard accessory ecosystem for tamper protection in public areas.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ctable class=\"specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAmerex Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e21481\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAmerex KP kitchen fire suppression systems\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eActivation Type\u003c\/td\u003e\n\u003ctd\u003eDual-action manual pull\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003eAmerex MRM and PRM release modules\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSurface or recessed\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed, NFPA 96, OEM Original\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance (NFPA 96)\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003ePlacement Requirements\u003c\/h3\u003e\n      \u003cp\u003ePer NFPA 96, the manual pull station must be located in the path of egress from the kitchen — within reach of the exit door and visible to kitchen personnel. The pull station must be clearly identified with a fire suppression system pull station sign indicating its purpose. Mount the 21481 at a height accessible to all kitchen staff. Placement that requires reaching over hot equipment or through a hazardous area to activate violates NFPA 96 accessibility requirements.\u003c\/p\u003e\n      \u003ch3\u003eConnection to MRM or PRM\u003c\/h3\u003e\n      \u003cp\u003eConnect the 21481 to the Amerex MRM or PRM module per the Amerex KP system manual wiring diagram. The pull station cable must be routed in a way that prevents accidental disconnection or damage from kitchen equipment, heat, or foot traffic. Verify correct pull station cable tension and release mechanism function during system commissioning and at every semi-annual inspection.\u003c\/p\u003e\n      \u003ch3\u003eSemi-Annual Inspection\u003c\/h3\u003e\n      \u003cp\u003ePer NFPA 17A and NFPA 96, verify the 21481 pull station cable is intact, the dual-action mechanism moves freely, and the pull station sign is clean and legible. The pull station guard should be present if installed. Test the pull station function using the Amerex-specified test procedure — do not perform a live discharge test without isolating the system from the agent cylinders first. Document the test in the fire suppression system inspection record.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\u003cdiv class=\"accordion-content-inner\"\u003e\n      \u003ch3\u003eWhat is the dual-action design and why is it required?\u003c\/h3\u003e\n      \u003cp\u003eThe dual-action mechanism requires the operator to perform two distinct motions to activate the pull station — typically lifting a guard and then pulling the handle. This prevents accidental activation by incidental contact in a busy kitchen environment where the pull station is mounted near foot traffic and equipment movement. NFPA 96 requires that manual activation of fire suppression systems be deliberate and intentional, making the dual-action design a code-required safety feature.\u003c\/p\u003e\n      \u003ch3\u003eIs a pull station guard required?\u003c\/h3\u003e\n      \u003cp\u003eA pull station guard is required when the manual pull station is installed in a location accessible to the public or in areas where accidental activation is a significant risk. In commercial kitchen environments where only trained staff have access, a pull station guard may not be required but is still recommended as a best practice. The Amerex pull station guard accessories are available separately and are sized to fit the 21481.\u003c\/p\u003e\n      \u003ch3\u003eCan the 21481 be used with Pyro-Chem systems?\u003c\/h3\u003e\n      \u003cp\u003eNo. The 21481 is specifically designed and listed for Amerex KP systems with MRM or PRM modules. Pyro-Chem systems use their own fire suppression pull station hardware that is listed and calibrated for Pyro-Chem release modules. Using cross-brand pull stations voids the UL 300 system listing. Always match fire suppression supply components to the system manufacturer.\u003c\/p\u003e\n    \u003c\/div\u003e\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  document.querySelectorAll('.accordion-header').forEach(h =\u003e h.addEventListener('click', function() { this.parentElement.classList.toggle('active'); }));\n});\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Amerex 21481 KP Manual Pull Station | OEM | Kitchen Fire Suppression\",\n  \"description\": \"UL Listed OEM dual-action manual pull station for Amerex KP kitchen fire suppression systems. Compatible with Amerex MRM and PRM release modules. Surface or recessed mounting. NFPA 96 placement in egress path required. Semi-annual inspection per NFPA 17A and NFPA 96. Pull station guard available separately. Not compatible with Pyro-Chem systems. Amerex Corporation original.\",\n  \"sku\": \"21481\", \"mpn\": \"21481\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"Amerex\" },\n  \"manufacturer\": { \"@type\": \"Organization\", \"name\": \"Amerex Corporation\" },\n  \"category\": \"Fire Suppression Equipment\"\n}\n\u003c\/script\u003e\n\n\u003c\/body\u003e","brand":"Amerex","offers":[{"title":"Default Title","offer_id":45957817729189,"sku":"21481","price":114.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/amerex-default-title-21481-amerex-kp-manual-pull-station-33394377293989_14ae8f1f-fe93-4ce3-b247-3571b4a49556.webp?v=1771286590"},{"product_id":"ansul-remote-pull-station-without-wire-rope-434618","title":"Ansul Remote Pull Station (Without Wire Rope) 434618","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eAnsul Remote Pull Station | Part No. 434618 | Without Wire Rope\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Ansul Remote Pull Station (434618) is a mission-critical manual activation component designed for the Ansul R-102 and PIRANHA restaurant fire suppression systems. In the sophisticated architecture of a commercial kitchen, the pull station is the primary human interface. While automated fusible links are designed to trigger during a thermal event, the 434618 allows kitchen staff to initiate a total system discharge at the first visual sign of an uncontrollable flare-up, potentially saving thousands of dollars in structural damage by stopping a fire before it enters the exhaust plenum.\u003c\/p\u003e\n        \u003cp\u003eConstructed from a high-impact, molded red composite, the 434618 is engineered for the hot zone of the professional kitchen. Unlike metal pull stations that can corrode when exposed to caustic degreasers, this composite housing remains vibrant and functional for decades. This specific model is provided without wire rope, offering contractors the ultimate flexibility to customize cable lengths for large-scale manifolds without the waste of pre-cut leads.\u003c\/p\u003e\n\n        \u003ch3\u003eKinetic Tension Transfer\u003c\/h3\u003e\n        \u003cp\u003eThe 434618 operates on a purely mechanical principle. When the handle is pulled, it exerts a linear force on the internal 1\/16\" stainless steel cable. This tension travels through a network of pulley elbows to the Automan release mechanism, where it trips the sear and fires the nitrogen cartridge.\u003c\/p\u003e\n\n        \u003ch3\u003eFail-Safe Reliability\u003c\/h3\u003e\n        \u003cp\u003eBecause the 434618 is a non-electrical device, it is immune to the power-failure trap. In the event of a kitchen fire that trips the building's main circuit breakers, the 434618 remains fully operational. It does not rely on batteries or capacitors; it relies on the physics of mechanical leverage.\u003c\/p\u003e\n\n        \u003ch3\u003eComposite Durability vs. Thermal Expansion\u003c\/h3\u003e\n        \u003cp\u003eIn high-heat environments, metal enclosures can expand and bind the pull-handle. The Ansul 434618 composite material is thermally stable, ensuring the handle pulls smoothly even if the ambient temperature has spiked due to proximity to a charbroiler or oven.\u003c\/p\u003e\n\n        \u003ch3\u003eCompliance with NFPA 17A and 96\u003c\/h3\u003e\n        \u003cp\u003eThese standards dictate that a manual pull station must be readily accessible and located along a path of egress. The 434618's high-visibility red finish and standardized PULL instructions ensure that even temporary staff can identify the fire trigger instantly during a high-stress emergency.\u003c\/p\u003e\n\n        \u003ch3\u003eADA-Compliant Mounting Profile\u003c\/h3\u003e\n        \u003cp\u003eWhen installed at the mandated height of 42 to 48 inches above the floor, the 434618 meets the forward reach requirements of the Americans with Disabilities Act (ADA). This ensures the fire safety system is accessible to all employees, regardless of physical ability.\u003c\/p\u003e\n\n        \u003ch3\u003eCustom Installation Flexibility\u003c\/h3\u003e\n        \u003cp\u003eBy purchasing the 434618 without wire rope, contractors can minimize splice-failure risks. Technicians can pull a single, continuous run of cable from the pull station directly to the control head, reducing potential snag-points in the conduit.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Applications \u0026 Use Cases --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Restaurant Lines:\u003c\/strong\u003e Providing the mandatory manual override for fryer, griddle, and range protection.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstitutional Kitchens (Schools\/Hospitals):\u003c\/strong\u003e Ensuring a robust safety infrastructure that passes the most rigorous public health audits.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHotel \u0026amp; Resort Banquet Facilities:\u003c\/strong\u003e Where long conduit runs require the no wire rope flexibility of the 434618 for custom architectural layouts.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eShow Kitchens:\u003c\/strong\u003e Utilizing the 427074 trim ring for a professional, recessed look that blends into high-end interior designs.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eFood Trucks and Mobile Units:\u003c\/strong\u003e A compact, rugged manual trigger that withstands the vibrations of mobile food service.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003eAnsul\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e434618\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eMaterial\u003c\/td\u003e\n              \u003ctd\u003eHigh-Impact Molded Red Composite\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n              \u003ctd\u003eAnsul R-102, PIRANHA\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eComponent Type\u003c\/td\u003e\n              \u003ctd\u003eManual Actuator (Remote)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eIncluded Hardware\u003c\/td\u003e\n              \u003ctd\u003ePull station assembly only (No wire rope)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCertifications\u003c\/td\u003e\n              \u003ctd\u003eUL Listed, ULC Listed, CE Approved\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: Maintenance \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eMaintenance \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eSemi-Annual Inspection Protocol\u003c\/h3\u003e\n        \u003cp\u003eEvery 6 months, a certified fire technician must verify the pull station is unobstructed and that the break-glass seal is intact.\u003c\/p\u003e\n\n        \u003ch3\u003eFunctional Pull-Test\u003c\/h3\u003e\n        \u003cp\u003eDuring system testing, the technician should perform a live-pull (with the cartridge removed) to ensure the cable slides freely. Grease buildup inside the conduit is a common cause of stiff-pull failures.\u003c\/p\u003e\n\n        \u003ch3\u003eVisual Calibration\u003c\/h3\u003e\n        \u003cp\u003eEnsure the pull station is mounted at the correct height and located within the path of egress, typically 10 to 20 feet from the hood.\u003c\/p\u003e\n\n        \u003ch3\u003eCleaning Protocol\u003c\/h3\u003e\n        \u003cp\u003eUse only mild soap and water. Avoid harsh abrasives that could dull the high-visibility finish or obscure the instructional text.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 5: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eWhy does this model not include the wire rope?\u003c\/h3\u003e\n        \u003cp\u003eThe no wire rope configuration is designed for professional installers who prefer to use bulk spools. This allows for a single, continuous cable run from the pull station to the Automan, which is more reliable than using pre-cut lengths that may require splicing.\u003c\/p\u003e\n\n        \u003ch3\u003eCan I install this pull station directly inside the hood plenum?\u003c\/h3\u003e\n        \u003cp\u003eNo. The remote pull station must be located away from the immediate fire hazard so an operator can safely reach it without exposure to flames. The standard distance is 10 to 20 feet from the protected equipment.\u003c\/p\u003e\n\n        \u003ch3\u003eDo I need a special tool to reset the pull station?\u003c\/h3\u003e\n        \u003cp\u003eOnce pulled, the internal cable tension must be reset at the Automan control head using a cocking tool. The handle can be pushed back into the set position, but the system will not be armed until a new break-glass seal is installed by a professional.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Ansul Remote Pull Station (Without Wire Rope)\",\n  \"description\": \"UL Listed manual actuator remote pull station for Ansul R-102 and PIRANHA fire suppression systems. High-impact molded red composite housing. Sold without wire rope for custom continuous cable runs. ADA-compliant mounting profile. CE Approved. Non-electrical fail-safe design maintains full operation during power failures.\",\n  \"sku\": \"434618\",\n  \"mpn\": \"434618\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Ansul\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Ansul (A Johnson Controls Brand)\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Part Number\",\n      \"value\": \"434618\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Material\",\n      \"value\": \"High-Impact Molded Red Composite\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"System Compatibility\",\n      \"value\": \"Ansul R-102, PIRANHA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Component Type\",\n      \"value\": \"Manual Actuator (Remote)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Included Hardware\",\n      \"value\": \"Pull station assembly only (No wire rope)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"UL Listed, ULC Listed, CE Approved\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"Ansul","offers":[{"title":"Default Title","offer_id":47379711131813,"sku":"434618","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/RemotePullStation_96de240e-68e7-40eb-9a44-79ec0bb2b260.webp?v=1771286481"},{"product_id":"ansul-remote-manual-pull-station-spanish-ver-436361","title":"Ansul Remote Manual Pull Station (Spanish Ver.) - 436361","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eAnsul Remote Manual Pull Station | Part No. 436361 | Spanish Instruction Series\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Ansul Remote Manual Pull Station with Spanish Instructions (436361) is a mission-critical life-safety component engineered for the Ansul R-102 suppression architecture. In the sophisticated hierarchy of fire safety, the manual pull station serves as the definitive command interface. While automatic detection systems rely on the thermal melting of fusible links, the 436361 allows on-site personnel to initiate a full system discharge instantly.\u003c\/p\u003e\n        \u003cp\u003eSpecifically designed for multicultural environments, the 436361 features high-visibility Spanish-language safety legends (\"EN CASO DE INCENDIO - HALAR Y BAJAR\"). In a high-stress emergency, the cognitive load of translating instructions can lead to fatal hesitations. By providing clear, native-language guidance, this pull station ensures that the activation process is intuitive for all staff members. As a UL-listed mechanical device, it provides a direct-drive mechanical link to the AUTOMAN release, ensuring the suppression agent is deployed regardless of the facility's electrical status.\u003c\/p\u003e\n\n        \u003ch3\u003eTension-Break Logic\u003c\/h3\u003e\n        \u003cp\u003eThe 436361 operates on a tension-break logic principle. It is connected to the release mechanism via a 1\/16-inch stainless steel wire rope. When the handle is pulled, the mechanical force is transmitted through a series of corner pulleys to the firing pin of the propellant cartridge. This direct-drive mechanical link is immune to digital failures such as power surges or battery death.\u003c\/p\u003e\n\n        \u003ch3\u003eThermal Latency Bypass\u003c\/h3\u003e\n        \u003cp\u003eAutomatic fusible links require the ambient temperature at the plenum to reach a specific thermal activation threshold before they actuate. A mechanical manual release allows the operator to trigger the system at the first sight of a flare-up, knocking down flames before they enter the exhaust ductwork and preventing a localized incident from becoming a structural disaster.\u003c\/p\u003e\n\n        \u003ch3\u003eSynchronized Mechanical Pulse\u003c\/h3\u003e\n        \u003cp\u003eUpon actuation, the 436361 initiates a synchronized safety sequence that triggers the gas shut-off valve and toggles the electrical microswitches required to shut down exhaust fans, effectively starving the fire of both fuel and oxygen simultaneously.\u003c\/p\u003e\n\n        \u003ch3\u003eMultilingual Fire Instruction\u003c\/h3\u003e\n        \u003cp\u003eThe Spanish instruction series on the 436361 recognizes the demographic reality of the modern culinary workforce. By providing multilingual fire instruction, the facility manager reduces the risk of human error during the emergency response, where the speed of response is inversely proportional to the complexity of instructions.\u003c\/p\u003e\n\n        \u003ch3\u003eCorrosion-Resistant Composite Housing\u003c\/h3\u003e\n        \u003cp\u003eThe 436361 is housed in a high-impact, corrosion-resistant composite housing that resists grease caking, ensuring the handle remains movable and the Spanish-language safety legend remains legible for the entire service life of the system.\u003c\/p\u003e\n\n        \u003ch3\u003eEgress Point Positioning\u003c\/h3\u003e\n        \u003cp\u003eThe 436361 is designed for surface mounting at a distance of 10 to 20 feet from the hood. This positioning ensures the operator is far enough from the flames to remain safe while maintaining accessibility so the station can be pulled while evacuating the hazard zone.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Applications \u0026 Use Cases --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Commercial Kitchens:\u003c\/strong\u003e Where Spanish is a primary or secondary language spoken by the culinary team.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstitutional Dining (Hospitals\/Stadiums):\u003c\/strong\u003e Providing a human-initiated fail-safe in facilities with high personnel density.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eIndustrial Manufacturing Zones:\u003c\/strong\u003e Protecting hazardous areas where mechanical reliability is preferred over electronic sensors.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRemote Kiosks:\u003c\/strong\u003e Where a power-independent manual trigger is required for standalone suppression systems.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eModernization Retrofits:\u003c\/strong\u003e Replacing older English-only stations to meet current inclusive fire safety best practices and local AHJ preferences.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003eAnsul\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e436361\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eLanguage Series\u003c\/td\u003e\n              \u003ctd\u003eSpanish Instruction Series\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eLegend Text\u003c\/td\u003e\n              \u003ctd\u003eEN CASO DE INCENDIO - HALAR Y BAJAR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eActivation Type\u003c\/td\u003e\n              \u003ctd\u003eMechanical Manual Release\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCable Compatibility\u003c\/td\u003e\n              \u003ctd\u003e1\/16\" Stainless Steel Wire Rope\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eHousing Material\u003c\/td\u003e\n              \u003ctd\u003eCorrosion-Resistant Composite Housing\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompliance\u003c\/td\u003e\n              \u003ctd\u003eUL 300, ULC Listed, FM Approved\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: Installation \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eThe 42-to-48 Mounting Rule\u003c\/h3\u003e\n        \u003cp\u003ePer ADA and NFPA standards, the operable part of the pull station must be mounted between 42 inches and 48 inches above the finished floor. This ensures accessibility for all personnel.\u003c\/p\u003e\n\n        \u003ch3\u003eConspicuity Audit\u003c\/h3\u003e\n        \u003cp\u003eThe 436361 must be unobstructed. If equipment blocks the station, it is a significant code violation. Technicians must verify the station is conspicuous from the cooking line.\u003c\/p\u003e\n\n        \u003ch3\u003eThe Silent Pull Audit\u003c\/h3\u003e\n        \u003cp\u003eDuring the mandatory 6-month inspection, the technician must pull the 436361 while the system is locked out. This verifies that the cable moves freely through every corner pulley in the run.\u003c\/p\u003e\n\n        \u003ch3\u003eMechanical Pull-Down Sequence Verification\u003c\/h3\u003e\n        \u003cp\u003eTechnicians must verify that the mechanical pull-down sequence is smooth and that the internal tamper seal is replaced during every service cycle.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 5: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan I use the 436361 for an Amerex or Buckeye system?\u003c\/h3\u003e\n        \u003cp\u003eNo. The 436361 is specifically listed for Ansul R-102 and PIRANHA systems. The internal mechanical stroke is calibrated for the Ansul AUTOMAN release. Mixing brands is a major code violation.\u003c\/p\u003e\n\n        \u003ch3\u003eDoes this station come with the wire rope?\u003c\/h3\u003e\n        \u003cp\u003eNo. The 1\/16-inch stainless steel cable and associated routing hardware are sold separately to allow for custom layout lengths.\u003c\/p\u003e\n\n        \u003ch3\u003eWhy is a manual station required if the system is automatic?\u003c\/h3\u003e\n        \u003cp\u003eA human can often see a fire before the thermal links reach their activation threshold. Manual activation provides a head-start that can be the difference between a minor cleanup and a total facility loss.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Ansul Remote Manual Pull Station | Spanish Instruction Series\",\n  \"description\": \"UL 300 listed mechanical manual pull station for Ansul R-102 and PIRANHA fire suppression systems. Spanish-language legend: EN CASO DE INCENDIO - HALAR Y BAJAR. Direct-drive 1\/16 inch stainless steel wire rope connection to AUTOMAN release. Corrosion-resistant composite housing. Power-independent operation. FM Approved, ULC Listed. Wire rope sold separately.\",\n  \"sku\": \"436361\",\n  \"mpn\": \"436361\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Ansul\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Ansul (A Johnson Controls Brand)\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Part Number\",\n      \"value\": \"436361\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Language Series\",\n      \"value\": \"Spanish Instruction Series\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Legend Text\",\n      \"value\": \"EN CASO DE INCENDIO - HALAR Y BAJAR\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Activation Type\",\n      \"value\": \"Mechanical Manual Release\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Compatibility\",\n      \"value\": \"1\/16 inch Stainless Steel Wire Rope\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Corrosion-Resistant Composite Housing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compliance\",\n      \"value\": \"UL 300, ULC Listed, FM Approved\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"Ansul","offers":[{"title":"Default Title","offer_id":47487172608165,"sku":null,"price":93.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/AnsulRemoteManualPullStation_SpanishVer._-436361_6ecfcfe0-934a-4f1c-bbd5-19f1a5444786.webp?v=1771286424"},{"product_id":"pyro-chem-double-action-pull-station-551166","title":"Pyro-Chem Double Action Pull Station - 551166","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003ePyro-Chem RPS-E2 Double Action Pull Station | Part No. 551166 | Electrical Series\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Pyro-Chem Double Action Pull Station (551166), designated as Model RPS-E2, is a mission-critical manual command station engineered for the Kitchen Knight II and Monarch industrial fire suppression systems. In the sophisticated architecture of fire safety, the RPS-E2 serves as the human fail-safe. While automatic detection systems rely on thermal fusible links or electronic sensors, the RPS-E2 allows on-site personnel to initiate a full suppression discharge instantly from a safe distance, such as a designated point of egress.\u003c\/p\u003e\n        \u003cp\u003eDesigned for high-traffic and high-vibration industrial environments, the 551166 utilizes a double-action mechanical gate. By requiring two distinct physical movements to actuate, the RPS-E2 virtually eliminates the risk of accidental triggering. For facility managers, the RPS-E2 is more than a pull station; it is a rugged manual override interface designed to protect against costly system downtime.\u003c\/p\u003e\n\n        \u003ch3\u003eTactile Intentionality\u003c\/h3\u003e\n        \u003cp\u003eIn a standard single-action station, a single snag of a cleaning cloth can trigger a discharge. The RPS-E2 requires push-and-pull mechanics, a push in of the front plate followed by a pull down of the handle. This mechanical sequence ensures that actuation is a result of deliberate human intent, providing essential nuisance trip mitigation.\u003c\/p\u003e\n\n        \u003ch3\u003eDie-Cast Structural Integrity\u003c\/h3\u003e\n        \u003cp\u003eUnlike consumer-grade plastic units, the 551166 is constructed from a heavy-duty, corrosion-resistant die-cast metal alloy. This is critical in environments where aerosolized grease and caustic cleaning chemicals can degrade plastic over time. The metal housing ensures the hinges and switch mechanisms remain viable for the entire service life of the system.\u003c\/p\u003e\n\n        \u003ch3\u003eHigh-Visibility Fire Red Finishing\u003c\/h3\u003e\n        \u003cp\u003eThe unit is finished with a high-impact, oven-cured fire red powder coat. This ensures the station remains visible through thick smoke or during power failures, guiding personnel to the manual release point when seconds count.\u003c\/p\u003e\n\n        \u003ch3\u003eSPST Switch Architecture\u003c\/h3\u003e\n        \u003cp\u003eThe unit features a high-reliability single pole single throw (SPST) switch. When the handle is pulled, the switch completes the circuit, sending a low-voltage signal to the Electric Control Head (ECH3) or the system's main control panel.\u003c\/p\u003e\n\n        \u003ch3\u003eSupervised Circuitry Dynamics\u003c\/h3\u003e\n        \u003cp\u003eIn a professional installation, the RPS-E2 is typically wired with an end-of-line resistor (EOLR). The control panel constantly monitors the circuit for continuity. If the wiring is cut or the station is tampered with, the resistance changes and the panel triggers a trouble signal, ensuring the system does not sit in a dead state.\u003c\/p\u003e\n\n        \u003ch3\u003eECH Coordination\u003c\/h3\u003e\n        \u003cp\u003eUpon receiving the signal from the 551166, the Electric Control Head triggers a pneumatic actuation cartridge. This pulse travels through the manifold to the agent cylinders, initiating a total discharge. This electrical setup is ideal for complex layouts where routing mechanical cables around multiple corners would be impossible.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Applications \u0026 Use Cases --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Commercial Kitchens:\u003c\/strong\u003e Positioned near exits to serve as the chef's final fail-safe for the Kitchen Knight II system.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eIndustrial Paint Spray Booths:\u003c\/strong\u003e The electrical nature of the RPS-E2 allows it to be placed outside the hazardous vapor zone of a Monarch system.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eHazardous Material Storage:\u003c\/strong\u003e Providing a rugged, vibration-resistant manual trigger for chemical lockers where accidental release would be catastrophic.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eInstitutional Facilities:\u003c\/strong\u003e Protecting massive cooking lines where manual activation points must be networked across large distances.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRetrofit Modernization:\u003c\/strong\u003e Upgrading older mechanical pull systems to electrical supervision to meet modern building codes.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003ePyro-Chem (A Johnson Controls Brand)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e551166 (Model RPS-E2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eAction Type\u003c\/td\u003e\n              \u003ctd\u003eDual-Action Pull Station\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSwitch Configuration\u003c\/td\u003e\n              \u003ctd\u003eSingle Pole Single Throw (SPST)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eConstruction\u003c\/td\u003e\n              \u003ctd\u003eHeavy-Duty Die-Cast Metal\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFinish\u003c\/td\u003e\n              \u003ctd\u003eFire Red Powder Coat\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompatibility\u003c\/td\u003e\n              \u003ctd\u003eKitchen Knight II \/ Monarch Series\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompliance\u003c\/td\u003e\n              \u003ctd\u003eUL Listed, FM Approved, CSFM Listed\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: Installation \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eInstallation \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eThe 6-Month Functional Audit\u003c\/h3\u003e\n        \u003cp\u003eEvery six months, a technician must perform a functional test. Using a silent test mode, the technician ensures the SPST switch sends the correct signal without firing the agent cylinders.\u003c\/p\u003e\n\n        \u003ch3\u003ePath of Egress Accessibility\u003c\/h3\u003e\n        \u003cp\u003eNFPA standards mandate that the 551166 be unobstructed and located along the natural path of exit. If a remodel has moved the exit, the path of egress accessibility must be re-verified.\u003c\/p\u003e\n\n        \u003ch3\u003eTamper Seal Verification\u003c\/h3\u003e\n        \u003cp\u003eMost jurisdictions require a visual tamper indicator (break-tie). During maintenance, technicians replace these seals to provide the Fire Marshal with proof that the system remains untampered.\u003c\/p\u003e\n\n        \u003ch3\u003eADA Mounting Heights\u003c\/h3\u003e\n        \u003cp\u003eTo ensure accessibility, the RPS-E2 should be mounted between 42 to 48 inches from the floor. The unit fits a standard 2x4 electrical backbox, or a specific red metal backbox for surface-mounted industrial applications.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 5: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan I use the RPS-E2 with an Ansul R-102 system?\u003c\/h3\u003e\n        \u003cp\u003eNo. While both brands are owned by Johnson Controls, the RPS-E2 is specifically listed for Pyro-Chem hardware. Mixing manufacturers is a significant code violation and will void your UL listing.\u003c\/p\u003e\n\n        \u003ch3\u003eWhat is the difference between single and double action?\u003c\/h3\u003e\n        \u003cp\u003eA single-action station is pull only. A dual-action pull station like the 551166 requires two steps (push then pull). This second step is the industry's primary defense against expensive accidental discharges in busy work zones.\u003c\/p\u003e\n\n        \u003ch3\u003eDoes the station come with a backbox?\u003c\/h3\u003e\n        \u003cp\u003eThe 551166 fits a standard 2x4 electrical backbox. For surface-mounted industrial applications, a specific red metal backbox is often used to maintain the die-cast structural integrity and aesthetic.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Pyro-Chem RPS-E2 Double Action Pull Station\",\n  \"description\": \"UL Listed dual-action electrical pull station for Pyro-Chem Kitchen Knight II and Monarch fire suppression systems. Heavy-duty die-cast metal with fire red powder coat finish. SPST switch for supervised low-voltage signal to Electric Control Head (ECH3). Requires push-then-pull actuation for nuisance trip mitigation. Mounts to standard 2x4 electrical backbox. FM Approved, CSFM Listed.\",\n  \"sku\": \"551166\",\n  \"mpn\": \"551166\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Pyro-Chem\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Pyro-Chem (A Johnson Controls Brand)\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Part Number\",\n      \"value\": \"551166 (Model RPS-E2)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Action Type\",\n      \"value\": \"Dual-Action Pull Station\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Switch Configuration\",\n      \"value\": \"Single Pole Single Throw (SPST)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Construction\",\n      \"value\": \"Heavy-Duty Die-Cast Metal\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Finish\",\n      \"value\": \"Fire Red Powder Coat\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compatibility\",\n      \"value\": \"Kitchen Knight II \/ Monarch Series\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compliance\",\n      \"value\": \"UL Listed, FM Approved, CSFM Listed\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"PyroChem","offers":[{"title":"Default Title","offer_id":47487226347685,"sku":null,"price":107.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/Pyro-ChemDoubleActionPullStation-551166_eda8f9ef-3662-4bac-9e4f-1fe7f815b7f0.webp?v=1771286423"},{"product_id":"ansul-remote-manual-pull-station-without-dual-block-with-50ft-wire-rope-437244","title":"Ansul Remote Manual Pull Station without Dual Block with 50ft Wire Rope - 437244","description":"\u003cp\u003eAnsul Remote Manual Pull Station without Dual Block with 50ft Wire Rope \u003c\/p\u003e\n\u003cp\u003eP\/N: 437244\u003c\/p\u003e","brand":"Ansul","offers":[{"title":"Default Title","offer_id":47777141981349,"sku":null,"price":159.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/AnsulRemoteManualPullStationwithoutDualBlockwith50ftWireRope-437244.png?v=1777578465"},{"product_id":"ansul-remote-manual-pull-station-with-50ft-wire-rope-435960","title":"Ansul Remote Manual Pull Station with 50ft Wire Rope - 435960","description":"\u003cp\u003eAnsul Remote Manual Pull Station with 50ft Wire Rope\u003c\/p\u003e\n\u003cp\u003eP\/N: 435960\u003c\/p\u003e","brand":"Ansul","offers":[{"title":"Default Title","offer_id":47777377321125,"sku":null,"price":189.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/AnsulRemoteManualPullStationwith50ftWireRope-435960.png?v=1777579479"}],"url":"https:\/\/profireandsafety.com\/collections\/system-components-pull-stations.oembed","provider":"Pro Fire and Safety","version":"1.0","type":"link"}