{"product_id":"1-2-in-x-10-ft-electric-metallic-tube-emt-conduit","title":"1\/2 in. x 10 ft. Electric Metallic Tube (EMT) Conduit","description":"\u003cdiv class=\"ansul-product-section\"\u003e\n  \u003cstyle\u003e\n    .ansul-product-section {\n      max-width: 100%;\n      margin: 2rem 0;\n      font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\n      color: #333;\n    }\n    \n    .accordion-item {\n      border-bottom: 1px solid #e5e5e5;\n    }\n    \n    .accordion-item:first-child {\n      border-top: 1px solid #e5e5e5;\n    }\n    \n    .accordion-header {\n      display: flex;\n      justify-content: space-between;\n      align-items: center;\n      padding: 2.25rem 0;\n      cursor: pointer;\n      background: none;\n      border: none;\n      width: 100%;\n      text-align: left;\n      transition: background-color 0.3s ease;\n    }\n    \n    .accordion-header:hover {\n      background-color: #1a1a1a;\n    }\n    \n    .accordion-header:hover .accordion-title,\n    .accordion-header:hover .accordion-icon {\n      color: #ffffff;\n    }\n    \n    .accordion-title {\n      font-size: 1.5rem;\n      font-weight: 500;\n      color: #1a1a1a;\n      letter-spacing: 0.02em;\n      margin: 0;\n      transition: color 0.3s ease;\n    }\n    \n    .accordion-icon {\n      font-size: 1.875rem;\n      font-weight: 300;\n      color: #666;\n      transition: transform 0.3s ease, color 0.3s ease;\n      line-height: 1;\n    }\n    \n    .accordion-item.active .accordion-icon {\n      transform: rotate(180deg);\n    }\n    \n    .accordion-content {\n      max-height: 0;\n      overflow: hidden;\n      transition: max-height 0.3s ease, padding 0.3s ease;\n      padding: 0;\n    }\n    \n    .accordion-item.active .accordion-content {\n      max-height: 5000px;\n      padding-bottom: 1.5rem;\n    }\n    \n    .accordion-content-inner {\n      font-size: 1.40625rem;\n      line-height: 1.7;\n      color: #555;\n    }\n    \n    .accordion-content-inner p {\n      margin: 0 0 1.5rem 0;\n    }\n    \n    .accordion-content-inner p:last-child {\n      margin-bottom: 0;\n    }\n    \n    .accordion-content-inner h3 {\n      font-size: 1.40625rem;\n      font-weight: 600;\n      color: #333;\n      margin: 1.875rem 0 1.125rem 0;\n    }\n    \n    .accordion-content-inner ul {\n      margin: 1.125rem 0 1.5rem 0;\n      padding-left: 2.25rem;\n    }\n    \n    .accordion-content-inner li {\n      margin-bottom: 0.75rem;\n      line-height: 1.6;\n      font-size: 1.40625rem;\n    }\n    \n    .accordion-content-inner ol {\n      margin: 1.125rem 0 1.5rem 0;\n      padding-left: 2.25rem;\n    }\n    \n    .accordion-content-inner ol li {\n      margin-bottom: 0.75rem;\n      line-height: 1.6;\n      font-size: 1.40625rem;\n    }\n    \n    .specs-table {\n      width: 100%;\n      border-collapse: collapse;\n      margin: 1.5rem 0 0 0;\n    }\n    \n    .specs-table tr {\n      border-bottom: 1px solid #e5e5e5;\n    }\n    \n    .specs-table tr:last-child {\n      border-bottom: none;\n    }\n    \n    .specs-table td {\n      padding: 1.3125rem 0;\n      font-size: 1.40625rem;\n      vertical-align: top;\n    }\n    \n    .specs-table td:first-child {\n      font-weight: 600;\n      color: #333;\n      width: 40%;\n      padding-right: 2.25rem;\n    }\n    \n    .specs-table td:last-child {\n      color: #555;\n    }\n\n    \/* Responsive *\/\n    @media (max-width: 768px) {\n      .accordion-header {\n        padding: 1.875rem 0;\n      }\n\n      .accordion-title {\n        font-size: 1.25rem;\n      }\n\n      .specs-table td:first-child {\n        width: 45%;\n        padding-right: 1.5rem;\n      }\n\n      .specs-table td {\n        padding: 1.125rem 0;\n        font-size: 1.25rem;\n      }\n\n      .accordion-content-inner {\n        font-size: 1.25rem;\n      }\n\n      .accordion-content-inner li {\n        font-size: 1.25rem;\n      }\n    }\n  \u003c\/style\u003e\n\n  \u003cdiv class=\"accordion\"\u003e\n    \u003c!-- Product Overview --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\" aria-expanded=\"false\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eProduct Overview\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eThe 1\/2 in. x 10 ft. Electric Metallic Tube (EMT) conduit is the essential foundation for safe, compliant, and durable electrical distribution systems. Often referred to by contractors as \"thin-wall\" conduit, EMT is a lightweight yet high-strength raceway designed to house and protect electrical conductors. In commercial, industrial, and residential settings, the 1\/2-inch trade size is the most widely utilized dimension, providing the perfect balance of internal capacity for branch circuits and a slim profile for efficient routing.\u003c\/p\u003e\n          \n          \u003cp\u003eManufactured from high-grade galvanized steel, this 10-foot conduit section is more than just a protective sleeve; it is a critical component of a building's safety architecture. It safeguards sensitive wiring from physical impact, moisture, and fire, ensuring that power and life-safety systems—such as fire alarms and emergency lighting—remain operational under stress. For B2B stakeholders, including property managers and electrical contractors, the 1\/2 in. EMT represents the industry standard for cost-effective, code-compliant infrastructure.\u003c\/p\u003e\n\n          \u003ch3\u003eThe Engineering of Physical Protection and EMI Shielding\u003c\/h3\u003e\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eGalvanized Corrosion Resistance:\u003c\/strong\u003e The steel is treated with a specialized zinc coating via a galvanization process. This prevents oxidation (rust) from compromising the conduit's wall thickness. In damp environments or utility rooms, this coating ensures the conduit remains a continuous, reliable enclosure for the life of the building.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Interference (EMI) Shielding:\u003c\/strong\u003e One of the most overlooked benefits of steel EMT is its ability to reduce electromagnetic interference. Steel conduit can shield sensitive data and communication lines from the \"noise\" generated by nearby power cables, a vital feature in modern \"smart\" offices and industrial automation centers.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003ePhysical Impact Resilience:\u003c\/strong\u003e Unlike PVC or flexible non-metallic tubing (ENT), EMT provides a rigid barrier that resists punctures from tools, furniture movement, and accidental impacts in high-traffic areas like warehouses or mechanical closets.\u003c\/li\u003e\n          \u003c\/ul\u003e\n\n          \u003ch3\u003eB2B Value: Streamlining Installation and Code Compliance\u003c\/h3\u003e\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eThreadless Integration:\u003c\/strong\u003e Unlike Rigid Metal Conduit (RMC), EMT is threadless. It utilizes set-screw or compression-style fittings, which significantly reduces installation time. This \"fast-track\" assembly allows contractors to meet tight project deadlines without sacrificing system safety.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eField Manipulability:\u003c\/strong\u003e The 1\/2-inch trade size is exceptionally easy to manipulate. It can be cut with a standard hacksaw or tube cutter and shaped with a manual hand bender. This allows for precision offsets and \"saddles\" to navigate around existing HVAC ductwork or structural beams.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eThe Equipment Grounding Path (NEC 250):\u003c\/strong\u003e Under specific conditions defined by the NEC, properly installed EMT conduit and its associated metallic fittings can serve as the Equipment Grounding Conductor (EGC). This eliminates the need to pull an additional green ground wire, saving both material costs and conduit fill space.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Applications \u0026 Use Cases --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\" aria-expanded=\"false\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eApplications \u0026amp; Use Cases\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eThe 1\/2-inch EMT is a versatile \"Universal Raceway\" found in nearly every modern construction sector:\u003c\/p\u003e\n\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCommercial Offices:\u003c\/strong\u003e Routing branch circuits for workstations, lighting, and HVAC controls above drop ceilings or within wall cavities.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eIndustrial Facilities:\u003c\/strong\u003e Protecting power runs for small machinery, sensors, and conveyor system controls where mechanical damage is a constant risk.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eLife-Safety Systems:\u003c\/strong\u003e The mandatory choice for protecting wiring for Fire Alarm Control Panels (FACP), smoke detectors, and strobe notification appliances.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eResidential Garages \u0026amp; Basements:\u003c\/strong\u003e Providing a professional, \"exposed-work\" solution for adding outlets or lighting in areas where Romex (NM-B) cable cannot be used due to physical hazard risks.\u003c\/li\u003e\n          \u003c\/ul\u003e\n\n          \u003ch3\u003eConductor Fill and Thermal Safety (NEC Article 358)\u003c\/h3\u003e\n          \u003cp\u003eTo remain compliant and prevent electrical fires, facility managers must adhere to Conductor Fill regulations. Overfilling a 1\/2 in. EMT conduit prevents heat from dissipating, which can lead to insulation failure.\u003c\/p\u003e\n          \n          \u003cp\u003e\u003cstrong\u003eThe 40% Rule:\u003c\/strong\u003e For three or more conductors, the total area of the wires must not exceed 40% of the internal area of the conduit.\u003c\/p\u003e\n          \n          \u003cp\u003e\u003cstrong\u003eCapacity Guide:\u003c\/strong\u003e For standard THHN\/THWN-2 wiring, 1\/2 in. EMT typically accommodates:\u003c\/p\u003e\n          \u003cul\u003e\n            \u003cli\u003e9 Conductors of #14 AWG\u003c\/li\u003e\n            \u003cli\u003e6 Conductors of #12 AWG\u003c\/li\u003e\n            \u003cli\u003e4 Conductors of #10 AWG\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Technical Specifications --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\" aria-expanded=\"false\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eTechnical Specifications\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003ctable class=\"specs-table\"\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eTrade Size\u003c\/td\u003e\n                \u003ctd\u003e1\/2 Inch\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eLength\u003c\/td\u003e\n                \u003ctd\u003e10 Feet (120 inches)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eMaterial\u003c\/td\u003e\n                \u003ctd\u003eGalvanized Steel (High-Strength)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eInside Diameter\u003c\/td\u003e\n                \u003ctd\u003eApprox. 0.622 inches\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eOutside Diameter\u003c\/td\u003e\n                \u003ctd\u003eApprox. 0.706 inches\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eCompliance\u003c\/td\u003e\n                \u003ctd\u003eUL 797, ANSI C80.3, NEC Article 358\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eWall Thickness\u003c\/td\u003e\n                \u003ctd\u003eApprox. 0.042 inches\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Compliance \u0026 Safety --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\" aria-expanded=\"false\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eCompliance \u0026amp; Safety\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003eTo maintain OSHA and NFPA standards, EMT systems should undergo periodic inspection:\u003c\/p\u003e\n\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eSupport \u0026amp; Strapping:\u003c\/strong\u003e Per NEC 358.30, EMT must be securely fastened within 3 feet of every termination (outlet box, panel, etc.) and every 10 feet thereafter.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCoupling Integrity:\u003c\/strong\u003e In high-vibration industrial settings, set-screws can occasionally loosen. Inspections should verify that all couplings remain tight to maintain the continuous grounding path.\u003c\/li\u003e\n            \u003cli\u003e\n\u003cstrong\u003eCorrosion Monitoring:\u003c\/strong\u003e While galvanized, EMT in damp locations should be checked for \"white rust\" or surface oxidation that could eventually lead to wall thinning.\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- FAQ --\u003e\n    \u003cdiv class=\"accordion-item\"\u003e\n      \u003cbutton class=\"accordion-header\" aria-expanded=\"false\"\u003e\n        \u003ch3 class=\"accordion-title\"\u003eFAQ\u003c\/h3\u003e\n        \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n      \u003c\/button\u003e\n      \u003cdiv class=\"accordion-content\"\u003e\n        \u003cdiv class=\"accordion-content-inner\"\u003e\n          \u003cp\u003e\u003cstrong\u003eIs 1\/2 in. EMT conduit fire-rated?\u003c\/strong\u003e\u003cbr\u003e\n          EMT itself is non-combustible. While it doesn't have a \"hour-rating\" like a fire door, it is a recognized component in fire-rated assemblies. It does not contribute fuel to a fire and does not emit toxic smoke, unlike PVC conduit.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eCan I run 1\/2 in. EMT underground?\u003c\/strong\u003e\u003cbr\u003e\n          Generally, no. For direct burial or concrete encasement, PVC (Schedule 40 or 80) or Rigid Metal Conduit (RMC) with proper coating is required. EMT is designed for interior use or exterior use with specialized fittings.\u003c\/p\u003e\n\n          \u003cp\u003e\u003cstrong\u003eHow many 90-degree bends can I have in a single run?\u003c\/strong\u003e\u003cbr\u003e\n          Per NEC 358.26, the total number of bends between pull points (like a junction box or condulet) cannot exceed 360 degrees (four 90-degree bends). Exceeding this makes pulling wire nearly impossible without damaging the insulation.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cscript\u003e\n    document.addEventListener('DOMContentLoaded', function() {\n      const accordionHeaders = document.querySelectorAll('.accordion-header');\n      \n      accordionHeaders.forEach(header =\u003e {\n        header.addEventListener('click', function() {\n          const accordionItem = this.parentElement;\n          const isActive = accordionItem.classList.contains('active');\n          \n          \/\/ Toggle current item\n          accordionItem.classList.toggle('active');\n          this.setAttribute('aria-expanded', !isActive);\n        });\n      });\n    });\n  \u003c\/script\u003e\n\n  \u003c!-- JSON-LD Product Schema (hidden from customers) --\u003e\n  \u003cscript type=\"application\/ld+json\"\u003e\n  {\n    \"@context\": \"https:\/\/schema.org\/\",\n    \"@type\": \"Product\",\n    \"name\": \"1\/2 in. x 10 ft. Electric Metallic Tube (EMT) Conduit\",\n    \"description\": \"UL 797 Galvanized Steel - Essential foundation for safe, compliant electrical distribution systems with EMI shielding and corrosion resistance\",\n    \"sku\": \"EMT-1-2-10FT\",\n    \"mpn\": \"EMT-1-2-10FT\",\n    \"brand\": {\n      \"@type\": \"Brand\",\n      \"name\": \"Generic\"\n    },\n    \"manufacturer\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Various Manufacturers\"\n    },\n    \"additionalProperty\": [\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Trade Size\",\n        \"value\": \"1\/2 Inch\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Length\",\n        \"value\": \"10 Feet (120 inches)\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Material\",\n        \"value\": \"Galvanized Steel (High-Strength)\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Inside Diameter\",\n        \"value\": \"Approx. 0.622 inches\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Outside Diameter\",\n        \"value\": \"Approx. 0.706 inches\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Wall Thickness\",\n        \"value\": \"Approx. 0.042 inches\"\n      },\n      {\n        \"@type\": \"PropertyValue\",\n        \"name\": \"Certifications\",\n        \"value\": \"UL 797, ANSI C80.3, NEC Article 358\"\n      }\n    ],\n    \"category\": \"Electrical Conduit\"\n  }\n  \u003c\/script\u003e\n\u003c\/div\u003e","brand":"Pro Fire and Safety","offers":[{"title":"Default Title","offer_id":47511430168741,"sku":null,"price":8.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/Screenshot2026-02-19141046.png?v=1771535490","url":"https:\/\/profireandsafety.com\/products\/1-2-in-x-10-ft-electric-metallic-tube-emt-conduit","provider":"Pro Fire and Safety","version":"1.0","type":"link"}