{"product_id":"ansul-oem-valve-stem-for-co2-extinguishers-441004","title":"Ansul OEM Valve Stem for CO2 Extinguishers - 441004","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eAnsul 441004 Valve Stem | Sentry CO2 Series | High-Pressure Cryogenic Seal\u003c\/title\u003e\n\u003cstyle\u003e\n  .product-section {\n    max-width: 100%;\n    margin: 2rem 0;\n    font-family: Arial, sans-serif;\n    color: #333;\n  }\n  .accordion-item {\n    border-bottom: 1px solid #ddd;\n  }\n  .accordion-header {\n    display: flex;\n    justify-content: space-between;\n    padding: 2rem 0;\n    cursor: pointer;\n    background: none;\n    border: none;\n    width: 100%;\n    text-align: left;\n    color: #333;\n  }\n  .accordion-header:hover,\n  .accordion-header:focus {\n    color: #333;\n    background: none;\n    outline: none;\n  }\n  .accordion-title {\n    font-size: 1.5rem;\n    font-weight: 500;\n  }\n  .accordion-icon {\n    font-size: 1.5rem;\n  }\n  .accordion-item.active .accordion-icon {\n    transform: rotate(180deg);\n  }\n  .accordion-content {\n    max-height: 0;\n    overflow: hidden;\n  }\n  .accordion-item.active .accordion-content {\n    max-height: none;\n  }\n  .accordion-content-inner {\n    font-size: 1.4rem;\n    line-height: 1.7;\n    color: #555;\n    padding-bottom: 2rem;\n  }\n  .accordion-content-inner p {\n    margin: 0 0 1rem 0;\n  }\n  .accordion-content-inner ul {\n    margin: 0 0 1rem 0;\n    padding-left: 2rem;\n  }\n  .accordion-content-inner h3 {\n    font-size: 1.4rem;\n    font-weight: 600;\n    color: #333;\n    margin: 1.5rem 0 0.5rem 0;\n  }\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n  .specs-table th,\n  .specs-table td {\n    border: 1px solid #ddd;\n    padding: 0.75rem 1rem;\n    font-size: 1.4rem;\n    text-align: left;\n  }\n  .specs-table th {\n    background-color: #f5f5f5;\n    font-weight: 600;\n    color: #333;\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"product-section\"\u003e\n\n  \u003c!-- Section 1: Product Overview --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eProduct Overview\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003cp\u003eThe Ansul 441004 Valve Stem (A441004) is the specialized high-pressure gatekeeper of the Ansul Sentry Carbon Dioxide (CO2) extinguisher line. Unlike the valve stems found in standard dry chemical units, the 441004 is a precision-engineered mechanical assembly designed to manage the volatile vapor pressures of liquefied gas. While standard dry chemical units operate at a modest 195 PSI, CO2 cylinders are stored at approximately 850 PSI (58.6 bar) at room temperature, requiring a seal capable of maintaining gas-tight integrity under nearly five times the mechanical stress of traditional equipment.\u003c\/p\u003e\n        \u003cp\u003eIn high-stakes environments such as data centers, telecommunication hubs, and MRI suites, this valve stem represents the difference between a successful, residue-free suppression event and a leak-induced system failure. The 441004 replaces legacy part numbers 429154 and 418682, allowing service providers to standardize their fleet with a single modern SKU. As a universal replacement across the Sentry CD and CD-A series, it is the primary internal component replaced during the mandatory 5-year NFPA 10 maintenance cycle.\u003c\/p\u003e\n\n        \u003ch3\u003eVapor Pressure Management\u003c\/h3\u003e\n        \u003cp\u003eInside a CO2 cylinder, the agent exists in a saturated state and internal pressure rises directly with ambient temperature. The machined brass valve stem body and high-tensile valve spring provide the necessary re-seating force to prevent the micro-leaks that often occur during thermal expansion cycles in unheated mechanical rooms or direct sunlight.\u003c\/p\u003e\n\n        \u003ch3\u003eCold-Shock Resilience (Joule-Thomson Effect)\u003c\/h3\u003e\n        \u003cp\u003eWhen CO2 is discharged, it undergoes rapid expansion, causing the agent temperature to plummet to approximately -110°F (-79°C). Standard elastomers would turn brittle and shatter under this cold-shock, but the 441004 features an advanced cold-shock resistant elastomer that remains flexible at cryogenic temperatures. This ensures the valve can be shut off intermittently during tactical fire suppression without freezing open.\u003c\/p\u003e\n\n        \u003ch3\u003eDirect Legacy Integration\u003c\/h3\u003e\n        \u003cp\u003eAs a universal replacement for legacy part numbers 429154 and 418682, the 441004 allows service providers to modernize older Sentry CD and CD-A units. This standardization of fleet performance with a single SKU simplifies service inventory management across the mandated 5-year maintenance hardware cycles.\u003c\/p\u003e\n\n        \u003ch3\u003eNon-Conductive Agent Delivery\u003c\/h3\u003e\n        \u003cp\u003eCO2 is the preferred suppressant for data centers and electrical cabinets because it is non-conductive and leaves zero residue. Maintaining these units with the OEM 441004 ensures that non-conductive agent delivery systems remain ready to protect high-voltage equipment and imaging suites without risk of equipment damage.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 2: Technical Specifications --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eTechnical Specifications\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ctable class=\"specs-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth\u003eFeature\u003c\/th\u003e\n              \u003cth\u003eDetails\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eManufacturer\u003c\/td\u003e\n              \u003ctd\u003eAnsul\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePart Number\u003c\/td\u003e\n              \u003ctd\u003e441004 (A441004)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eLegacy Cross-Reference\u003c\/td\u003e\n              \u003ctd\u003eReplaces 429154 and 418682\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCompatibility\u003c\/td\u003e\n              \u003ctd\u003eAnsul Sentry CD \u0026amp; CD-A Series (5 lb, 10 lb, 15 lb, 20 lb)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eOperating Media\u003c\/td\u003e\n              \u003ctd\u003eCarbon Dioxide (CO2)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eOperating Pressure\u003c\/td\u003e\n              \u003ctd\u003e~850 PSI (58.6 bar) at 70°F\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eMaterial\u003c\/td\u003e\n              \u003ctd\u003eMachined Brass and Stainless Steel\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSeal Type\u003c\/td\u003e\n              \u003ctd\u003eCold-Shock Resistant Elastomer\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eService Interval\u003c\/td\u003e\n              \u003ctd\u003e5-Year Maintenance Hardware Cycle (NFPA 10)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eCertifications\u003c\/td\u003e\n              \u003ctd\u003eUL Listed, OEM Original Equipment\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 3: Maintenance \u0026 Compliance --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eMaintenance \u0026amp; Compliance\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eThe Visilox V-711 Mandate\u003c\/h3\u003e\n        \u003cp\u003eTo maintain a gas-tight seal at 850 PSI, a very light coating of Visilox V-711 silicone lubricant must be applied to the stem's O-rings. Petroleum-based lubricants must be avoided, as they can react with high-pressure elastomers and degrade the seal's structural integrity.\u003c\/p\u003e\n\n        \u003ch3\u003eSeating Area Verification\u003c\/h3\u003e\n        \u003cp\u003eDuring the 5-year internal exam, the technician must meticulously clean the internal brass valve seat. Even a microscopic scratch can allow high-pressure CO2 gas to bypass the cold-shock resistant elastomer, resulting in a slow-leaker that will fail the next monthly inspection.\u003c\/p\u003e\n\n        \u003ch3\u003eSpring Fatigue Assessment\u003c\/h3\u003e\n        \u003cp\u003eThe high-tensile valve spring should be checked for set or fatigue during every recharge. A weak spring will fail to provide the re-seating force required to overcome the Joule-Thomson cooling during an intermittent discharge.\u003c\/p\u003e\n\n        \u003ch3\u003eNitrogen Blow-Down\u003c\/h3\u003e\n        \u003cp\u003eAfter cleaning the valve body and before installing the new 441004 valve stem, use dry nitrogen to blow out any moisture or debris from the valve's internal channels.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section 4: FAQ --\u003e\n  \u003cdiv class=\"accordion-item\"\u003e\n    \u003cbutton class=\"accordion-header\"\u003e\n      \u003cspan class=\"accordion-title\"\u003eFAQ\u003c\/span\u003e\n      \u003cspan class=\"accordion-icon\"\u003e⌄\u003c\/span\u003e\n    \u003c\/button\u003e\n    \u003cdiv class=\"accordion-content\"\u003e\n      \u003cdiv class=\"accordion-content-inner\"\u003e\n        \u003ch3\u003eCan I use the 429099 stem in my CO2 extinguisher?\u003c\/h3\u003e\n        \u003cp\u003eNo. The 429099 is designed for low-pressure (195 PSI) dry chemical units. Using it in a high-pressure CO2 cylinder is a catastrophic safety risk. The 850 PSI seal integrity required for CO2 would likely cause the low-pressure seals and springs of the 429099 to fail, leading to an uncontrolled discharge.\u003c\/p\u003e\n\n        \u003ch3\u003eWhy was the 441004 introduced to replace older part numbers?\u003c\/h3\u003e\n        \u003cp\u003eThe Ansul 441004 utilizes an advanced synthetic elastomer that offers superior resistance to compression set (permanent flattening). It is specifically optimized for vapor pressure management to prevent the valve from sticking after the extreme temperature drops associated with high-velocity CO2 discharge.\u003c\/p\u003e\n\n        \u003ch3\u003eWhat models are compatible with the 441004?\u003c\/h3\u003e\n        \u003cp\u003eThis stem is the standard for the entire modern Ansul Sentry Carbon Dioxide line, including the 5 lb, 10 lb, 15 lb, and 20 lb CD and CD-A (aluminum) models.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cscript\u003e\ndocument.addEventListener('DOMContentLoaded', function() {\n  const headers = document.querySelectorAll('.accordion-header');\n  headers.forEach(header =\u003e {\n    header.addEventListener('click', function() {\n      this.parentElement.classList.toggle('active');\n    });\n  });\n});\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Ansul 441004 Valve Stem | Sentry CO2 Series\",\n  \"description\": \"UL Listed OEM machined brass and stainless steel valve stem with cold-shock resistant elastomer seal for Ansul Sentry CD and CD-A CO2 extinguishers (5 lb to 20 lb). Rated approximately 850 PSI (58.6 bar). Replaces legacy parts 429154 and 418682. Mandatory replacement at 5-year NFPA 10 internal maintenance cycle. Silicone lubricant only; petroleum lubricants prohibited.\",\n  \"sku\": \"441004\",\n  \"mpn\": \"441004\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Ansul\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Ansul (A Johnson Controls Brand)\"\n  },\n  \"category\": \"Fire Suppression Equipment\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Part Number\",\n      \"value\": \"441004 (A441004)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Legacy Cross-Reference\",\n      \"value\": \"Replaces 429154 and 418682\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compatibility\",\n      \"value\": \"Ansul Sentry CD \u0026 CD-A Series (5 lb, 10 lb, 15 lb, 20 lb)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Operating Pressure\",\n      \"value\": \"~850 PSI (58.6 bar) at 70 degrees F\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Material\",\n      \"value\": \"Machined Brass and Stainless Steel\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Seal Type\",\n      \"value\": \"Cold-Shock Resistant Elastomer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Service Interval\",\n      \"value\": \"5-Year Maintenance Hardware Cycle (NFPA 10)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"UL Listed, OEM Original Equipment\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","brand":"Ansul","offers":[{"title":"Default Title","offer_id":47424007405733,"sku":null,"price":6.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/5605\/8021\/files\/Ansul_441004_single_valve_stem.webp?v=1781214815","url":"https:\/\/profireandsafety.com\/products\/ansul-oem-valve-stem-for-co2-extinguishers-441004","provider":"Pro Fire and Safety","version":"1.0","type":"link"}