4 Pack of 5LB Ansul ABC Dry Chem Fire Extinguishers
Are you a fire protection company? Get wholesale pricing at HedrickPro
Wholesale PricingThe Ansul Sentry 5 lb ABC fire extinguisher represents the gold standard in portable, multi-purpose fire protection for professional environments. Designed to meet the rigorous demands of commercial, industrial, and light business sectors, this unit is not a typical home-use disposable canister. It is a rugged, rechargeable life-safety tool engineered to suppress fires involving ordinary combustibles, flammable liquids, and energized electrical equipment.
This 4-pack bundle ensures that your facility maintains consistent, uniform protection across multiple zones, keeping you in compliance with fire codes while prioritizing the safety of your occupants and assets.
Comprehensive Fire Class Coverage: A, B, and C
The Ansul Sentry AA05S-1 is an ABC-rated unit formulated to tackle the three most common fire types found in commercial settings:
- Class A (Ordinary Combustibles): Effectively smothers fires fueled by wood, paper, cloth, rubber, and many plastics.
- Class B (Flammable Liquids and Gases): Interrupts the chemical chain reaction of fires fueled by gasoline, oils, oil-based paints, and flammable gases.
- Class C (Energized Electrical Equipment): Utilizes a non-conductive agent to safely extinguish fires involving electrical tools, appliances, and wiring without risking shock to the operator.
Why the 5 lb Capacity is the Commercial Industry Standard
The 5 lb capacity is frequently cited by safety professionals as the sweet spot of fire protection. Smaller 2.5 lb units are easier to store but often lack the discharge duration to fully extinguish a developing commercial fire. Larger 10 lb and 20 lb units can be heavy and difficult for some employees to operate effectively under stress.
- Increased Discharge Time: Provides approximately 13 to 15 seconds of steady extinguishing power.
- Extended Range: Allows the operator to stand at a safer distance of typically 10 to 15 feet while attacking the base of the fire.
- Manageable Weight: At a total weight of roughly 10 lbs per unit including the 5 lb agent, it is manageable for the vast majority of staff members to lift and maneuver.
This 4-pack is tailored for property managers and business owners who need to protect specific square footage across multiple zones.
Offices and Retail Spaces
Mount these near exits and in corridors to meet NFPA 10 requirements for travel distance. The corrosion-resistant finish ensures they complement professional environments without appearing industrial or obtrusive.
Auto Repair and Service Shops
The ABC rating is vital here for managing both wood and cardboard fires and potential grease or oil flare-ups. The Class B rating specifically addresses the unique hazards of automotive fluids and solvents.
Mechanical and Electrical Rooms
Protecting HVAC systems, servers, and electrical panels requires the Class C rating found in the Sentry series. The non-conductive dry chemical agent allows safe suppression without risk of electrical shock.
Institutional Use
Schools, churches, and public buildings benefit from the Sentry's reputation for reliability and ease of inspection. The clear pressure gauge and accessible safety pin make monthly visual inspections straightforward for facility managers.
Engineered for Longevity: Steel Construction vs. Plastic Alternatives
- Steel Cylinder: The AA05S-1 features a high-grade steel shell coated with a corrosion-resistant powder finish, designed to withstand the humidity and temperature fluctuations of industrial settings.
- Metal Valve Assembly: The robust metal valve allows for multiple recharges. If the unit is discharged, a fire safety professional can refill it, making it a sustainable, long-term investment rather than a single-use product.
| Feature | Details |
|---|---|
| Manufacturer | Ansul (A Johnson Controls Brand) |
| Model Number | Sentry AA05S-1 |
| Agent Type | Monoammonium Phosphate (ABC Dry Chemical) |
| Agent Capacity | 5 lbs per unit (20 lbs total in 4-pack) |
| UL Fire Rating | 3-A:40-B:C |
| Cylinder Material | High-Strength Steel with Powder-Coat Finish |
| Valve Material | Aluminum and Metal Alloy |
| Discharge Time | Approximately 14 Seconds |
| Effective Range | 10 to 15 Feet |
| Operating Temperature | -40°F to 120°F (-40°C to 49°C) |
| Total Weight (Filled) | Approximately 10 lbs per unit |
| Rechargeable | Yes |
| Mounting | Wall hook bracket included |
| Certifications | UL Listed, OSHA Compliant, NFPA 10, DOT Approved |
To remain compliant with OSHA and NFPA 10 regulations, fire extinguishers must be properly maintained and regularly inspected. The Ansul Sentry series is designed to streamline compliance while ensuring operational readiness.
Monthly Visual Inspections
- Check the pressure gauge to ensure it is in the green zone
- Confirm the safety pin is intact and the tamper seal is unbroken
- Ensure no physical damage is visible on the cylinder or hose
- Verify the unit is accessible and the mounting bracket is secure
Annual Maintenance
- A certified fire safety professional must inspect the internal mechanisms
- Verify the condition of the dry chemical agent
- Test the discharge mechanism and pressure release
- Update the inspection tag with the current date and technician information
6-Year and 12-Year Service
The Sentry series undergoes internal examination at the 6-year mark and hydrostatic testing at 12 years to ensure the steel cylinder remains safe under pressure. These milestone inspections verify structural integrity and extend the operational lifespan of your investment.
Regulatory Compliance
- UL Listed: Meets Underwriters Laboratories standards for fire extinguisher performance and safety.
- OSHA Compliant: Satisfies OSHA requirements for workplace fire safety equipment.
- NFPA 10: Adheres to National Fire Protection Association standards for installation, inspection, and maintenance.
- DOT Approved: Cylinder construction meets Department of Transportation specifications for pressurized vessels.
How do I mount these for maximum accessibility?
Each unit in this 4-pack comes with a standard wall hook. For high-traffic areas, mount them so the handle is no higher than 5 feet from the floor to ensure all staff members can reach them.
What is the shelf life of an Ansul Sentry extinguisher?
Dry chemical agents do not expire in the traditional sense, but they can settle over time. With professional annual maintenance and proper storage, these units can last 12 to 20 or more years.
Can these be used in cold environments?
Yes. The Sentry AA05S-1 is rated for temperatures as low as -40°F, making it suitable for unheated warehouses and outdoor storage sheds.